Specifications and Parts List
Environmental Specifications
The DECserver 90L+ is designed to operate in an office environment or equipment
room environment such as, telephone closets or satellite equipment rooms. It is
not intended to operate in an air plenum.
Operating Environment
The operating environment for the DECserver 90L+ is as follows:
Item
Value
Temperature
5° C to 50° C (41° F to 122 ° F)
Maximum rate of change
20° C/hr (68° F/hr)
Relative humidity
10 % to 95 % (non-condensing)
Wet-bulb temperature
32° C ( 90° F) maximum
Dew point
2° C (36° F) minimum
Altitude
Sea level to 2.4 km (8000 ft)
Air flow
Convectively cooled. A minimum of 10 cm(4 in) of
space must be provided on both ends of the unit for
adequate air flow.
Shipping Environment
The shipping environment for the DECserver 90L+ is as follows:
Item
Value
Temperature
-40° C to 66° C (-40 ° F to 151 °F)
Relative humidity
10 % to 95 % (non-condensing)
Altitude
Sea level to 4.9 km ( 16000 ft)
A–2 Specifications and Parts List