5
Troubleshooting the DECserver 90L+
This chapter describes how to troubleshoot the DECserver 90L+. To troubleshoot
your unit:
1.
Verify that the unit is properly installed.
2.
Note the fault condition.
3.
Isolate the problem. Use Table 5–1 as a guide to determine the probable
cause and the suggested solution.
Table 5–1 DECserver 90L+ Troubleshooting
If...
Then...
Do this...
The power LED is not
‘‘on’’
The DECserver 90L+
is not receiving proper
voltage.
Check the AC power connection
and verify that the AC outlet
is working. Check the power
connection on the DECserver 90L+.
If the problem still exists, replace
the power supply.
The self-test LED is not
‘‘on’’
The unit did not pass
self-test.
Replace the unit.
The network LED is not
‘‘on’’
The unit’s network
connector is not properly
terminated.
Check network connection.
Check if the segment is properly
terminated.
Disconnect unit from network.
Connect T-connector with two
50 ohm terminators. If the
LED lights, then it is a network
problem. Otherwise, replace the
unit.
(continued on next page)
Troubleshooting the DECserver 90L+ 5–1