MAINTENANCE
Replacing the Outer Primary and Inner
Safety Filters
1. Pull out the tab on the air cleaner housing
end cover.
End Cover Tab
2. Turn the end cover counter-clockwise to
unlock and pull the cover away from the
main air cleaner housing.
3. Remove the outer primary and inner safety
filters from the air cleaner housing.
Outer Primary Filter
Inner Safety Filter
4. Inspect the inside of the air cleaner housing
and the end cover for debris, and wipe
them down with a damp cloth as
necessary. DO NOT use compressed air to
blow out the inside of the air cleaner
housing. DO NOT allow dust to enter the
air intake tube when cleaning or replacing
parts.
5. Place the new inner safety filter into the air
cleaner housing until it is fully seated.
6. Place the new outer safety filter into the air
filter housing over the inner safety filter and
gently push the filter into the unit until it
feels secure.
7. Place the end cover tightly up against the
ridge at the end of the air cleaner housing.
8. Turn the end cover clockwise to lock the
cover onto the air cleaner housing, making
sure the dust ejector boot is in the vertical
position.
9. Push the tab in on the air cleaner housing
end cover to secure.
10. Press the restriction indicator reset button
on the restriction indicator after the unit has
been cleaned.
1000 Service Hours
Replace Radiator Coolant
Ensure the engine is turned OFF and cooled
down prior to replacing the radiator coolant
1. Unbolt the four cap screws attaching the
front radiator shroud to the radiator and
remove the shroud.
2. Place a drain pan under the radiator drain
valve.
Front Radiator Shroud
3. Slowly remove the radiator cap.
51