MAINTENANCE
Inspect all hydraulic hoses and fittings daily for
leaks. Remember to use cardboard or a piece
of paper when checking for leaks and replace
damaged components immediately.
Check Hydraulic Fluid Level for Hydro
Pump Assembly
Prior to checking the hydraulic fluid level,
ensure that there is no blade installed on the
saw and the saw frame is in a level position.
1. Check the hydro pump reservoir tank level.
Hydro Pump Reservoir Tank
2. If the level is below the “Cold Full” line
then, remove the reservoir tank cap.
3. Add SAE 15W-40 oil to the reservoir tank
fill line. DO NOT overfill as fluid will leak out
from the reservoir cap.
4. Replace the cap and tighten to secure.
Adding Fluid to the Hydraulic Lift Pump
Hydraulic Lift Pump Breather Cap
Check the fluid daily and add fluid to the pump
as necessary.
1. Lower the saw to level the frame.
2. Unlatch and lower the rear cover screen.
3. Remove the hydraulic pump breather cap.
4. Remove the hydraulic pump fill access plug
on the upper right side of the upright
assembly.
Hydraulic Pump Fill Access Cover
5. Using a funnel with flexible hose, add
SAE15W-40 oil or an equivalent to just
below where the fill port extends into the
hydraulic pump. Do not overfill, as this will
cause oil leakage through the breather cap
when raising the saw.
6. Replace the breather cap and retighten to
secure.
7. Close the rear cover screen and latch to
secure.
8. Replace the hydraulic pump fill access
plug.
Check Radiator Coolant Level
Prior to checking the radiator coolant level,
ensure that there is no blade installed on the
saw and the saw frame is in a level position.
1. Remove the radiator access cover plate by
unscrewing it from the top of the front
radiator shroud.
Radiator Access Cover