Invalid configuration information - please
run SETUP program
The system configuration information
does not match the hardware
configuration.
Enter
system setup
and correct the
system configuration information.
Keyboard clock line failure
Keyboard controller failure
Keyboard data line failure
Keyboard failure
Keyboard stuck key failure
A cable or connector may be loose,
or the keyboard or keyboard/mouse
controller may be faulty.
See "
Keyboard Problems
."
Memory address line failure at
address
,
read
value
expecting
value
One or more DIMMs may be faulty or
improperly seated.
See "
System Memory Problems
."
Memory allocation error
The software you are attempting to
run is conflicting with the operating
system or another application
program or utility.
Turn off the computer, wait 30 seconds,
and then turn it on. Try to run the program
again. If the problem persists, contact the
software company.
Memory data line failure at
address
, read
value
expecting
value
Memory double word logic failure at
address
, read
value
expecting
value
Memory odd/even logic failure at
address
,
read
value
expecting
value
Memory write/read failure at
address
, read
value
expecting
value
One or more DIMMs may be faulty or
improperly seated.
See "
System Memory Problems
."
Memory size in CMOS invalid
The amount of memory recorded in
the system configuration information
does not match the memory installed
in the computer.
Reboot the computer. If the error appears
again, see "
Getting Help
" for instructions
on obtaining technical assistance.
Memory tests terminated by keystroke
The memory test was not completed. Rerun the memory test.
No boot device available
The computer cannot find the
diskette or hard drive.
Enter
system setup
, check the system
configuration information for the diskette
and hard drive, and, if necessary, correct
the information.
No boot sector on hard-disk drive
The system configuration information
in system setup may be incorrect, or
the operating system may be
corrupted.
Enter
system setup
, check the system
configuration information for the hard
drive, and if necessary, correct the
information.
If the problem persists, reinstall your
operating system. See the
documentation that came with your
operating system.
No timer tick interrupt
A chip on the system board might be
malfunctioning.
Run the
System Board Devices
tests in
the
Dell Diagnostics
.
Non-system disk or disk error
The diskette in drive A or your hard
drive does not have a bootable
operating system installed on it.
A nonbootable diskette is in drive A.
Either replace the diskette with one that
has a bootable operating system, or
remove the diskette from drive A and
restart the computer.
Not a boot diskette
There is no operating system on the
diskette.
Boot the computer with a diskette that
contains an operating system.
Plug and Play Configuration Error
The system has encountered a
problem in trying to configure one or
more expansion cards.
Turn your system off and unplug it.
Remove all but one of the cards. Plug in
your system and reboot it. If the problem
persists, the expansion card may be
malfunctioning. If the message does not
reappear, turn off the power and reinsert
one of the other cards. Repeat this
process until you identify the
malfunctioning card.
Read fault
Requested sector not found
The operating system cannot read
from the diskette or hard drive.
The system could not find a particular
See "
Drive Problems
."