61
Select the destination that you want to save to, and enter the name that you want to give to the file, and then
click on “Save” in the usual way. After a few seconds the image will be saved and you can close the program
down.
External Interfaces
The SE-1000 has three external interfaces, RS-422, GPI and Tally.
RS-422 and GPI allow the SE-1000 to be controlled from an external device.
Tally provides information about the status of each of the Input Channels. The Datavideo TB-10 is able to
decode this data and feed tally information to tally lights, monitors such as the Datavideo TLM 433, or
talkback systems such as the Datavideo ITC-100.
Please see Useful Accessories for further details of TLM-433, TB-10, ITC-100
RS-422
RS-422 enables the SE-1000 to be controlled from external devices.
The RS-422 port is a sub d 9 pin port, and it is wired as follows:
Pin No.
Signal Type
Description
1
Frame Ground
Frame Ground
2
RXD (-)
Receive Data (-)
3
TXD (+)
Transmit Data (+)
4
Ground Ground
5
NC Not
Used
6
Ground Ground
7
RXD (+)
Receive Data (+)
8
TXD (-)
Transmit Data(-)
9
Frame Ground
Frame Ground
The transmission parameters are:
Baud Rate 38400
Parity ODD
Stop Bit 1 bit
The following functions can be controlled via RS-422. (Commands are compliant with GVG Protocol)
Crosspoint Switch
Wipe Pattern Selection
Transition Mode Selection (BKGD/KEY, MIX/WIPE)
Auto Transition Time Setting
Auto Transition Execute
Preset Memory Store / Recall