RG
SDI-12
•
Supports SDI-12 protocol versions 1.0 through 1.3 (auto-sensing)
•
Measure on Demand and Continuous Measurement modes
•
Includes facility for directly interrogating sensors for diagnostic purposes
Generic Serial Sensor Channel
•
Allows data to be logged from a wide range of smart sensors and data streams.
•
Flexible poll string generation and response parsing
•
Supports polled or unsolicited data
•
Includes facility for directly interrogating sensors for diagnostic purposes
Data Manipulation and Logging
Calculated Channels
•
Combine values from analog, digital and serial sensors using expressions involving variables and functions.
•
Functions: An extensive range of arithmetic, trigonometric, relational, logical and statistical functions are
available.
Alarms
•
Condition: high, low, within range and outside range, optional time specifier
•
Actions: set digital outputs, transmit message, and execute any DT80 command.
Schedules
•
Number of schedules: 11
•
Schedule types: immediate, continuous, periodic, time of day/week, polled, digital/counter/serial event, variable
change
•
Conditional schedule execution: digital state or variable
•
Periodic schedule rates: 10ms to days; synchronised to time of day
Data Storage
•
Internal memory capacity: 128MB or 2GB (upgradeable)
•
Removable USB 1.1/2.0 full speed memory device (optional accessory)
•
Data density: approx. 90,000 data points per megabyte.
Communication Interfaces
Ethernet Port
•
Interface: 10BaseT (10Mbps)
•
Protocol: TCP/IP
USB Port (not DT82)
•
Interface: USB 1.1/2.0 full speed (virtual COM port)
•
Protocols: ASCII command, TCP/IP (PPP), Modbus, Serial Sensor
Host RS232 Port (not DT8xM)
•
Speed: 300 to 115200 baud (57600 default)
•
Flow Control: Hardware (RTS/CTS), Software (XON/XOFF), None
•
Handshake lines: DCD, DSR, DTR, RTS, CTS
•
Modem support: auto-answer and dial out
•
Protocols: ASCII Command, TCP/IP (PPP), Modbus, Serial Sensor
Serial Sensor Port (not DT81/ 82E)
•
Interface: RS232, RS422, RS485
•
Speed: 300 to 57,600 baud
•
Flow Control: Hardware (RTS/CTS), Software (XON/XOFF), None
•
Protocols: ASCII Command, TCP/IP (PPP), Modbus, Serial Sensor