UM-0085-B09
DT80 Range User Manual
Page 141
RG
Controls vs. Profiles
The following table summarises the mapping between the controls described in this section and the
DT80
profile
settings, which are discussed in
and throughout this manual.
Category
Control
Default
Equivalent command language setting and default
Site
information Name
PROFILE USER SITE=
Regional
Mains frequency
50Hz
PROFILE PARAMETERS P11=50
Temperature units
°C
PROFILE PARAMETERS P36=0
Decimal point char
Standard
PROFILE PARAMETERS P38=46
Time & date
Time zone
0
PROFILE LOCALE TIME_ZONE=0S
Use NTP
no
PROFILE NTP BACKGROUND_ENABLE=NO
NTP server
0.datataker.pool.ntp.org
PROFILE NTP SERVER=0.datataker.pool.ntp.org
Update clock every
3599 s
PROFILE NTP BACKGROUND_PERIOD=3599S
Statistics
Stat. schedule rate
1s
RS1S
CEM
Number of CEMs
0
-
Power
Allow sleep
yes
PROFILE PARAMETERS P15=0
Delay until sleep
30 s
PROFILE PARAMETERS P17=30
Disable sleep if ext power yes
PROFILE PARAMETERS P15=0
Disable sleep if Eth/USB yes
PROFILE PARAMETERS P15=0
Power analog subsystem only when taking a reading
PROFILE PARAMETERS P21=0
Display backlight
on when key pressed
PROFILE PARAMETERS P20=2
12V power output
on when taking CEM
reading
PROFILE PARAMETERS P28=0
Security
Command server
enabled
PROFILE COMMAND_SERVER PORT=7700
FTP server
enabled
PROFILE FTP_SERVER PORT=21
HTTP server
enabled (fixed)
PROFILE HTTP_SERVER PORT=80
Modbus server
enabled
PROFILE MODBUS_SERVER TCPIP_PORT=502
FTP username
DATATAKER
PROFILE FTP_SERVER USER=DATATAKER
FTP password
DATATAKER
PROFILE FTP_SERVER PASSWORD=DATATAKER
Anonymous FTP
enabled
PROFILE FTP_SERVER ALLOW_ANONYMOUS=YES
Command password
PASSWORD=
Command timeout
600 s
PROFILE PARAMETERS P14=600
USB port
Function
command
PROFILE USB_PORT FUNCTION=COMMAND
Host port
Function
command
PROFILE HOST_PORT FUNCTION=COMMAND
Data rate
57600
PROFILE HOST_PORT BPS=57600
Data bits
8
PROFILE HOST_PORT DATA_BITS=8
Stop bits
1
PROFILE HOST_PORT STOP_BITS=1
Parity
none
PROFILE HOST_PORT PARITY=NONE
Flow control
software
PROFILE HOST_PORT FLOW=SOFTWARE
Flow control timeout
60 s
PROFILE PARAMETERS P26=60
Sensor port
Function
serial sensor
PROFILE SERSEN_PORT FUNCTION=SERIAL
Data rate
1200
PROFILE SERSEN_PORT BPS=1200
Data bits
8
PROFILE SERSEN_PORT DATA_BITS=8
Stop bits
1
PROFILE SERSEN_PORT STOP_BITS=1
Parity
none
PROFILE SERSEN_PORT PARITY=NONE
Mode
RS232
PROFILE SERSEN_PORT MODE=RS232
Flow control
none
PROFILE SERSEN_PORT FLOW=NONE
Flow control timeout
60 s
PROFILE PARAMETERS P26=60
Ethernet
Enable
yes
PROFILE ETHERNET ENABLE=YES
Auto-config
yes
PROFILE ETHERNET IP_ADDRESS=AUTO
Static IP address
0.0.0.0
PROFILE ETHERNET IP_ADDRESS=AUTO
Subnet mask
255.255.255.0
PROFILE ETHERNET SUBNET_MASK=255.255.255.0
Gateway address
0.0.0.0
PROFILE ETHERNET GATEWAY=0.0.0.0
Primary DNS
0.0.0.0
PROFILE NETWORK DNS_SERVER_1=0.0.0.0
Secondary DNS
0.0.0.0
PROFILE NETWORK DNS_SERVER_2=0.0.0.0
Ethernet
From name
PROFILE ETHERNET_SESSION SENDER_NAME=
Содержание DT80
Страница 29: ...UM 0085 B09 DT80 Range User Manual Page 29 RG The DT80 File System P114 ...
Страница 184: ...UM 0085 B09 DT80 Range User Manual Page 184 RG Figure 71 DT80 communications options ...
Страница 185: ...UM 0085 B09 DT80 Range User Manual Page 185 RG Figure 72 DT80 communications options integrated modem models ...