MATRIX 210™ REFERENCE MANUAL
110
8
The Parameter Setup window works in Interactive Mode in order to cause each parameter
setting to be immediately effective.
NOTE
If you want to save the temporary configuration to permanent memory, you
must first close the Calibration Tool window. Then, you must disable the
Interactive Mode and select the
Permanent Memory
option from the
Send
Configuration
item in the Device menu.
The following examples show some of the typical conditions occurring during the installation:
Under-exposure:
To correct this result it is recommended to change the following parameters in their order of
appearance:
1. increase the
Exposure Time
2. increase the
Gain
NOTE
In general, a longer exposure time corresponds to a lighter image but is
susceptible to blurring due to code movement. Exposure time is also limited
by the Internal Lighting mode parameter.
Longer exposure times can be
set if the power strobe level is lowered.
High gain settings may produce a grainy image that may affect the
decoding process.
Figure 115 - Example Under Exposure: Too Dark
Содержание Matrix 210
Страница 1: ...MATRIX 210 Reference Manual...
Страница 59: ...CBX ELECTRICAL CONNECTIONS 49 4 Figure 45 ID NET Network Connections with isolated power blocks...
Страница 60: ...MATRIX 210 REFERENCE MANUAL 50 4 Figure 46 ID NET Network Connections with Common Power Branch Network...
Страница 61: ...CBX ELECTRICAL CONNECTIONS 51 4 Figure 47 ID NET Network Connections with Common Power Star Network...
Страница 78: ...MATRIX 210 REFERENCE MANUAL 68 5 Figure 71 ID NET Network Connections with isolated power blocks...
Страница 79: ...25 PIN CABLE ELECTRICAL CONNECTIONS 69 5 Figure 72 ID NET Network Connections with Common Power Branch Network...
Страница 80: ...MATRIX 210 REFERENCE MANUAL 70 5 Figure 73 ID NET Network Connections with Common Power Star Network...
Страница 111: ...SOFTWARE CONFIGURATION 101 8 Figure 111 Options Communication Figure 112 Options Communication Ethernet...
Страница 142: ...www datalogic com...