25-PIN CABLE ELECTRICAL CONNECTIONS
67
5
5.5.2 ID-
NET™ Response Time
The following figure shows the response time of the ID-
NET™ network. This time is defined
as the period between the Trigger activation and the beginning of data transmission to the
Host.
Max ID-
NET™ Response Time
240
220
200
180
160
140
120
100
80
60
40
20
0
R
esponse Tim
e (m
s)
Number of Nodes
500 kbps
250 kbps
125 kbps
0
1
2
3
4
5
6
7
8
9
10 11
12 13 14 15 16
Figure 70
– ID-NET™ Response Time
CONDITIONS:
ID-
NET™ M/S Synchronized layout
message length = 50 bytes per node
Содержание Matrix 210