MATRIX 210™ REFERENCE MANUAL
58
4
4.7 EXTERNAL LIGHTING SYSTEMS
If an External Illuminator is used, it can be powered from the CBX connection box. It must be
connected to the
Vdc
and
GND
terminal clamps.
CAUTION
Power is available directly to the Illuminator, independently from the Power
Supply Switch inside the CBX.
In the case of the LT-700 illuminator, one of the available digital outputs must be connected
as the control signal. In VisiSet™, configure the Output Line Function parameter to "External
Lighting System" and the Matrix Output
x
External Lighting System Mode parameter to
"Triggered".
Control Signal for LT-700
illuminators
Power to External
Illuminator
Figure 60
– External Lighting System Connections
Below is a table summarizing the External Illuminator wiring and power requirements:
Illuminator
Wire Color
CBX/Matrix Signal
Meaning
LT-700
Red
Vdc
10 to 30 Vdc
Black
GND
Ground
White
Earth
Shield/Earth Ground
Green
O1- or O2-
Control Signal -
Yellow
O1+ or O2+
Control
Содержание Matrix 210
Страница 1: ...MATRIX 210 Reference Manual...
Страница 59: ...CBX ELECTRICAL CONNECTIONS 49 4 Figure 45 ID NET Network Connections with isolated power blocks...
Страница 60: ...MATRIX 210 REFERENCE MANUAL 50 4 Figure 46 ID NET Network Connections with Common Power Branch Network...
Страница 61: ...CBX ELECTRICAL CONNECTIONS 51 4 Figure 47 ID NET Network Connections with Common Power Star Network...
Страница 78: ...MATRIX 210 REFERENCE MANUAL 68 5 Figure 71 ID NET Network Connections with isolated power blocks...
Страница 79: ...25 PIN CABLE ELECTRICAL CONNECTIONS 69 5 Figure 72 ID NET Network Connections with Common Power Branch Network...
Страница 80: ...MATRIX 210 REFERENCE MANUAL 70 5 Figure 73 ID NET Network Connections with Common Power Star Network...
Страница 111: ...SOFTWARE CONFIGURATION 101 8 Figure 111 Options Communication Figure 112 Options Communication Ethernet...
Страница 142: ...www datalogic com...