MATRIX 210™ REFERENCE MANUAL
102
8
8.4 CONFIGURATION
Once connected to Matrix
210™ as described in par. 8.3, you can modify the configuration
parameters as follows:
1.
Press the Calibration Tool button from the Main Menu. Matrix
210™ will download its
permanent memory configuration parameters with the default values (if it is the first time)
to VisiSet™. The Calibration Tool window will be displayed together with the Parameter
Setup window working in Interactive Mode (see par. 8.4.1 and par. 8.4.3).
2.
Edit the Matrix
210™ configuration parameters according to your application
requirements.
3.
Use the
Calibration Tool
to fine tune the reading performance. See par. 8.4.3.
4.
Close the Calibration Tool window and disable the Interactive Mode by pressing the
interactive button.
5.
Save the new configuration to the reader permanent memory by pressing the Send
button.
NOTE
Especially for lengthy configurations in Interactive Mode, it is always good
practice to periodically send the configuration to
Permanent Memory
to
avoid losing the configuration in Temporary Memory.
6.
Close the Parameter Setup window and press
Disconnect
on the VisiSet™ menu bar
(see Figure 108) or launch
Run
Mode from the VisiSet™ Main menu.
Disconnect
exits closing communicat
ion between Matrix 210™ and VisiSet™, and
causes Matrix 210
™ to enter Run Mode. The disconnected reader serial port is now
available.
Run
command
does not close communication between Matrix 210™ and VisiSet™,
and causes Matrix 210™ to enter Run Mode. In this case the reader output messages
are displayed on the VisiSet™ terminal and the statistics are displayed in the
Statistics window (Statistics enabled).
Содержание Matrix 210
Страница 1: ...MATRIX 210 Reference Manual...
Страница 59: ...CBX ELECTRICAL CONNECTIONS 49 4 Figure 45 ID NET Network Connections with isolated power blocks...
Страница 60: ...MATRIX 210 REFERENCE MANUAL 50 4 Figure 46 ID NET Network Connections with Common Power Branch Network...
Страница 61: ...CBX ELECTRICAL CONNECTIONS 51 4 Figure 47 ID NET Network Connections with Common Power Star Network...
Страница 78: ...MATRIX 210 REFERENCE MANUAL 68 5 Figure 71 ID NET Network Connections with isolated power blocks...
Страница 79: ...25 PIN CABLE ELECTRICAL CONNECTIONS 69 5 Figure 72 ID NET Network Connections with Common Power Branch Network...
Страница 80: ...MATRIX 210 REFERENCE MANUAL 70 5 Figure 73 ID NET Network Connections with Common Power Star Network...
Страница 111: ...SOFTWARE CONFIGURATION 101 8 Figure 111 Options Communication Figure 112 Options Communication Ethernet...
Страница 142: ...www datalogic com...