2.3.2 ID-
NET™ Slave Management Through Master
When an ID-
NET™ layout has already been configured, it is possible to modify the
configuration of any Slave from VisiSet through the Master.
1.
Connect a PC equipped with VisiSet™ to the Main, or Auxiliary interface of the Master
reader.
2.
Launch VisiSet™ and connect to the Master reader.
3.
From the VisiSet™ Device Menu select "ID-NET™ Status Window" and click on the
"Look For Devices On Network" button to check the status of the expected Slave devices
within the ID-
NET™ network.
4. Click anywhere in the row of the specific slave in the ID-NET Status Window when its
Current Status is "Present". The Parameter Setup window will be displayed after a time
based on the network speed, with the configuration of the selected slave.
5. From the specific Slave Parameter Setup Window, change any parameter (not in
interactive mode), save the configuration to a file, or load a configuration from a file.
6. Send the modified configuration to the slave.
CAUTION
If a wrong configuration is set or if the Slave Reading System Layout
parameters are changed, the slave could lose the network connection.
Содержание Matrix 210
Страница 1: ...MATRIX 210 Reference Manual...
Страница 59: ...CBX ELECTRICAL CONNECTIONS 49 4 Figure 45 ID NET Network Connections with isolated power blocks...
Страница 60: ...MATRIX 210 REFERENCE MANUAL 50 4 Figure 46 ID NET Network Connections with Common Power Branch Network...
Страница 61: ...CBX ELECTRICAL CONNECTIONS 51 4 Figure 47 ID NET Network Connections with Common Power Star Network...
Страница 78: ...MATRIX 210 REFERENCE MANUAL 68 5 Figure 71 ID NET Network Connections with isolated power blocks...
Страница 79: ...25 PIN CABLE ELECTRICAL CONNECTIONS 69 5 Figure 72 ID NET Network Connections with Common Power Branch Network...
Страница 80: ...MATRIX 210 REFERENCE MANUAL 70 5 Figure 73 ID NET Network Connections with Common Power Star Network...
Страница 111: ...SOFTWARE CONFIGURATION 101 8 Figure 111 Options Communication Figure 112 Options Communication Ethernet...
Страница 142: ...www datalogic com...