Settings
B.1 Factory settings
86
SONO 3500 CT
Operating Instructions, 07/2019, VI.SH.P2.02
Measuring unit and factors
Flow unit factor
3600 (for flow unit m3/h)
Auto set from unit guide
Totalizer volume unit factor
1
Auto set from unit guide
Flow unit text
m
3
/h
Auto set from unit guide, but only m
3
/h
can be shown on display
Totalizer unit text
m
3
Auto set from unit guide, but only m
3
can be shown on display
Totalizer directions
Totalizer 1 direction
Forward
Forward/Reverse/Forward net/Reverse
net
Totalizer 2 direction
Reverse
Forward/Reverse/Forward net/Reverse
net
Digital output 1
Active
On
On/off
Direction
Forward
Forward/Reverse/Forward net/Reverse
net
Amount per pulse
0.1 m
3
Unit: The same as Totalizer unit
Value freely selectable
Pulse width
5 ms
5, 10, 20, 50, 100, 200, 500 ms
Digital Output 2
Active
On
On/off
Function
Alarm
Pulse/Alarm/Call up
Direction
No influence, while "Alarm"
Forward/Reverse/Forward net/Reverse
net
Amount per pulse
No influence, while "Alarm"
Unit: The same as Totalizer unit
Value freely selectable
Pulse width
No influence, while "Alarm"
5, 10, 20, 50, 100, 200, 500 ms
Содержание SONO 3500 CT
Страница 1: ...Ultrasonic Flowmeter Operating Instructions SONO 3500 CT 07 2019 Edition ...
Страница 2: ......
Страница 8: ...Table of contents 6 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 14: ...Introduction 1 5 Further Information 12 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 38: ...Electrical connection 5 5 Sealing of SONO 3500 CT 36 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 50: ...Commissioning 6 4 Commissioning via PDM 48 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 54: ...Functions 7 4 Hardware key 52 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 64: ...Service and maintenance 8 7 Battery disposal 62 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...