SONO 3500 CT
Operating Instructions, 07/2019, VI.SH.P2.02
85
Settings
B
B.1
Factory settings
The transmitter is from factory configured according to the order specification.
For the calibration / configuration of the flowmeter the application specific pipe dimensions
and the specific transducer locations can require an update.
Note
For type-approved and verified SONO 3500 CT flowmeter the settings are HW key protected
and therefore read only. This HW key is protected via the verification sealing. The verification
sealing can only be broken by the user with the acceptance of the local authorities.
Table B- 1
Factory settings
Identification
2-path factory settings (DN 50 to DN
1200)
Possible settings
Meter identification
-
Free text 15 characters
Application location
-
Free text 15 characters
Display menu
Menu 1 – 5 (all)
Menu 1 – 5, min one of the five
Pipe data
Number of paths
2
1 or 2
Inner pipe diameter (m)
for SONO 3500 CT factory pre-
configured according the order code
may not be changed
Q max
Qmax is 105% of Qs (Qs is shown on
the system nameplate). For SONO
3500 CT factory pre-configured accord-
ing the selection via the order code.
Adjustable
Low flow cut-off (% of Qmax)
0.25 %
For SONO 3500 CT factory pre-
configured. It is %-value related to the
Qmax setting. The %-value is equal to
50% of Qi (Qi is shown on the system
nameplate).
Adjustable between 0 … 10%
Filter time constant
Factory pre-configured to typical 5 s
(for larger pipe size higher values are
used)
Adjustable between 5 … 1000 s
Geometry factor path 1
For SONO 3500 CT factory pre-
configured according the order code
Auto set from pipe geometry help pro-
gram in PDM
Geometry factor path 2
For SONO 3500 CT factory pre-
configured according the order code
Auto set from pipe geometry help pro-
gram in PDM
Correction factor
Costumer correction factor
1
0.5 … 1.5
Содержание SONO 3500 CT
Страница 1: ...Ultrasonic Flowmeter Operating Instructions SONO 3500 CT 07 2019 Edition ...
Страница 2: ......
Страница 8: ...Table of contents 6 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 14: ...Introduction 1 5 Further Information 12 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 38: ...Electrical connection 5 5 Sealing of SONO 3500 CT 36 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 50: ...Commissioning 6 4 Commissioning via PDM 48 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 54: ...Functions 7 4 Hardware key 52 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 64: ...Service and maintenance 8 7 Battery disposal 62 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...