Parameter lists
A.3 Diagnostic
80
SONO 3500 CT
Operating Instructions, 07/2019, VI.SH.P2.02
Parameter
Default
value
Value
range
Access
level
Description
258
Leakage fault appears
e.g. 0 h
0 ... 65535 Read
First time the fault appeared.
Valid only if alarm is enabled
259
Leakage fault disappears
e.g. 0
0 ... 65535 Read
Last time the fault disappeared.
Valid only if alarm is enabled
260
Empty pipe alarm output
enable
Yes
No, Yes
R/W
Select "Yes" to enable active alarm on alarm
output / call-up
261
Empty pipe fault timer
e.g. 0 h
0 ... 65535 Read
Total hours fault active.
Valid only if alarm is enabled
262
Empty pipe fault counter
e.g. 0
0 ... 65535 Read
Total number of faults.
Valid only if alarm is enabled
263
Empty pipe fault appears
e.g. 0 h
0 ... 65535 Read
First time the fault appeared.
Valid only if alarm is enabled
264
Empty pipe fault disappears e.g. 0
0 ... 65535 Read
Last time the fault disappeared.
Valid only if alarm is enabled
Service
510
Fixed flow mode enable
Yes
No, Yes
R/W
Select "Yes" to force the device to show a
fixed flow value
Default must be "No"
Always manually reset the value to "No"
511
Fixed flow value
0
-1E+09 ...
1E+09
R/W
Fixed flow value for enabled fixed flow
515
Controlling output A and B Auto
Auto,
Forced
HW key Control of output A and B is used to stop or
force the output A and/or B.
For editing, use device menu "Service".
Valid if pulse output is enabled
Power
130
Consumed battery capacity e.g.
2.054239
Ah
Read
The amount of energy consumed since last
time the battery was replaced.
Valid only for battery-powered versions
501
Operating hours since pow-
er up
1105 h
3.4 E+38
Read
Total operation hours since first power up
503
Numbers of power up
e.g. 4
0 ... 65535 Read
Total number of power-ups since first pow-
er-up.
540
Battery change enable
No
No, Yes
R/W
Select "Yes" to set battery installation date
to current date and reset remaining battery
operation capacity to maximum.
Valid only for battery-powered versions
541
Battery installation date
last battery
installation
date
dd-mm-
yyyy;
hh:mm:ss
Read
Latest installation date of batteries.
Valid only for battery-powered versions
542
Power supply mode
Battery only Battery
only, Mains
only, Mains
with backup
battery.
Read
The flowmeter is either powered by battery
only, mains only or by mains with battery
backup.
The type is defined by the order code and
cannot be changed.
Содержание SONO 3500 CT
Страница 1: ...Ultrasonic Flowmeter Operating Instructions SONO 3500 CT 07 2019 Edition ...
Страница 2: ......
Страница 8: ...Table of contents 6 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 14: ...Introduction 1 5 Further Information 12 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 38: ...Electrical connection 5 5 Sealing of SONO 3500 CT 36 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 50: ...Commissioning 6 4 Commissioning via PDM 48 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 54: ...Functions 7 4 Hardware key 52 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 64: ...Service and maintenance 8 7 Battery disposal 62 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...