Parameter lists
A.2 Output
SONO 3500 CT
Operating Instructions, 07/2019, VI.SH.P2.02
75
Parameter
Default
value
Value range
Access
level
Description
106 Flow rate
Read
Actual flow value
107 Relative flow rate
0
Read
Actual flow value in relation to Qmax
108 Actual velocity for path 1
0
Read
The actual flow velocity for path 1 in m/s
(SI-unit)
109 Actual velocity for path 2
0
The actual flow velocity for path 2 in m/s
(SI-unit).
Valid for 2-path solutions only
110 Path 1 gain step
15
1 to 15
Read
Amplifier setting when measuring path 1
111 Path 2 gain step
15
1 to 15
Read
Amplifier setting when measuring path 2.
Valid for 2-path solutions only
Pulse A B
430 Output A enable
Yes
No, Yes
R/W
Select "Yes" to enable output A
431 Pulse A function
Forward
Forward, Re-
verse, Forward
net, Reverse net
R/W
Pulse output calculation on pure forward
flow or pure reverse flow - or net flow for
forward and reverse pulse flow.
Valid if pulse output A is enabled
432 Amount per pulse A
1.000000
(m
3
)
0.000001 ...
1000000000
R/W
Volume per pulse and selected unit
Valid if pulse output A is enabled.
433 Pulse width for pulse A
5 ms
5, 10, 20, 50,
100, 200, 500 ms
R/W
Pulse length when the pulse is active.
Valid if pulse output A is enabled
440 Output B enable
Yes
No, Yes
R/W
Select "Yes" to enable output B
441 Pulse B function
Alarm
Pulse, Alarm,
Call up
R/W
Configuration of output B as pulse -
alarm or call up function.
Valid if pulse output B is enabled
442 Pulse B direction
Reverse
Forward, Re-
verse, Forward
net, Reverse net.
R/W
Pulse output calculation on pure forward
flow or pure reverse flow - or net flow for
forward and reverse pulse flow.
Valid if pulse output B is enabled and
pulse function selected
443 Amount per pulse B
1.000000
(m
3
)
0.000001 ...
1000000000
R/W
Volume per pulse.
Valid if pulse output B is enabled and
pulse function selected
444 Pulse width for pulse B
5 ms
5, 10, 20, 50,
100, 200, 500 ms
R/W
Pulse length when the pulse is active.
Valid if pulse output B is enabled and
pulse function selected
Communication
For editing the communication settings, use PDM device menu "Communication Setting"
591 Device Communication Ad-
dress
1
1 ... 247
Read
Meter has default address value 1 with
selectable address up to 247
592 Baudrate
4
0 ... 5
Read
Communication port speed
593 Parity
0
0 ... 3
Read
Communication port parity
594 Interframe space
35
35 ... 255
Read
Minimum space between two messages
(bytes x 10)
595 Response delay
5
1 ... 50
Read
Minimum time from receiving a request
to its response
Содержание SONO 3500 CT
Страница 1: ...Ultrasonic Flowmeter Operating Instructions SONO 3500 CT 07 2019 Edition ...
Страница 2: ......
Страница 8: ...Table of contents 6 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 14: ...Introduction 1 5 Further Information 12 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 38: ...Electrical connection 5 5 Sealing of SONO 3500 CT 36 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 50: ...Commissioning 6 4 Commissioning via PDM 48 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 54: ...Functions 7 4 Hardware key 52 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 64: ...Service and maintenance 8 7 Battery disposal 62 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...