background image

Congratulations on your purchase of laser distance meter Vector 30 

CONDTROL.

Safety instructions can be found in the end of this user manual and should 

be carefully read before you use the device for the first time.

SAFETY REGULATIONS

The user manual should be read carefully before you use the device for 

the first time.  Unintended use of the device can be dangerous for human’s 

health and cause serious injury. Keep this user manual. If the device is given 

to somebody for temporary use, be sure to enclose user manual to it.

- Do not misuse the device. 

- Do not remove warning signs and protect them from abrasion, because 

they contain information about safe operation of the device. 

The device belongs to laser class 2 in accordance with EN60825-1.

Laser radiation!

Do not stare into beam

Class 2 laser

<1 mW 620-690nm

EN60825-1:2014

- Do not look into the laser beam or its reflection, with unprotected eye or 

through an optical instrument. Do not point the laser beam at people or 

animals without the need. You can dazzle them.

- To protect your eyes close them or look aside.

- It is prohibited to disassemble or repair the device yourself. Entrust the 

device repair to qualified personnel and use original spare parts only.

- Do not use the device in explosive environment, close to flammable 

materials.

- Avoid heating the batteries to avoid the risk of explosion and electrolyte 

leakage. In case of liquid contact with skin, wash it immediately with soap 

and water. In case of contact with eyes, flush with clean water during 10 

minutes and consult the doctor.

INTENDED USE

Laser distance meter Vector 30 is intended to measure distance, to 

calculate area and volume of measured objects and perform calculations 

by and Pythagoras’ Theorem. The device is suitable for use at both indoor 

and outdoor building areas.

TECHNICAL SPECIFICATIONS

Measuring range*

0,05…30 m

Smallest unit displayed

1 mm

Measuring accuracy **

±3 mm 

Laser 

Class II, 620-690 nm, <1 mW

Continuous measurement 

Addition/subtraction

+

Area/volume 

Calculations by Pythagoras’ Theorem

+

Automatic shutdown of the laser

30 seconds

Automatic shutdown of the device

180 seconds 

Battery life 

Up to 5000 measurements

Storage temperature

-20…+70 °С 

Operating temperature

0…+40 °С 

Dust and water protection rate

IP54

Power supply

2 х 1.5V AAA LR03 (alkaline) 

Dimensions

115х39х19 mm 

Weight

42 g

* Use a target plate to increase the measurement range during daylight or 

if the target has poor reflection properties.
** Accuracy can decrease under unfavorable conditions, such as intense 

sunshine or when measurements are made against glossy or transparent 

surfaces, moving objects, objects with rough surface or when laser beam 

is reflected. 

Vector 30 

 

User manual

Laser distance meter 

EN

DELIVERY PACKAGE

1. Laser distance meter – 1 pc.

2. Hand strap – 1 pc.

3. User manual – 1 pc.

4. Batteries 2 x 1.5V AAA LR03  

PRODUCT DESCRIPTION

Functions of buttons

Button

Short press 

Long press

1

Switch on the device/ switch on 

the laser beam/single distance 

measurement

Continuous 

measurement (tracking)

2

Area/volume/Pythagoras

Select measuring unit

3

Addition/subtraction

Select reference point

4

Delete the measurement result/exit 

the mode

Switch off the device

Display

1. Main line for displaying 

measurement/calculation 

results
2. Additional line for displaying 

measurement/calculation 

results
3. Indication of the mode 
4. Battery charge level 

indication
5. Measuring unit
6. Indication of the reference 

point 

OPERATION

Insert/replace batteries

Remove the battery cover. Insert the batteries, observing correct polarity. 

Put the battery cover back.

Replace the batteries as soon as the error 203 appears on the display.

Remove the batteries from the device if it’s not used for a long time to avoid 

corrosion and battery discharge. All batteries must be replaced at the same 

time. Both batteries must be of the same brand, with the same charge level.

Switch on/off

To switch on the device short press the button                        . The device will 
switch on and enter single distance measurement mode.

To switch off the device press and hold the button                    during 3 seconds. 

In order to save the battery power the device will switch off automatically 
within 180 seconds after the last operation.

Reference point

It is possible to set the reference point either from the top or the bottom 

end of the device.

The default reference point is the bottom end of the device.

To select the reference point press and hold the button                   during 2 

seconds.  Corresponding indicator will appear on the display –               or              .

Measuring unit

To select required measuring unit (m, in, ft) press and hold the button

during 2 seconds.

MEASUREMENTS

Single distance measurement

Short press the button                   to switch on the device. Laser beam will be 

switched on automatically. Aim the laser beam at the object of measurement 

and short press the button                   to make a single distance measurement.

Measurement result will appear on the display. Short press the button  

to delete the result of measurement and exit the mode.

Continuous measurement (tracking)

Press and hold the button                      during 3 seconds. 

The device will take measurements one after another, showing the last 

measured value in the main line, and the previous measured value in the first 

line. Short press the button                   to stop measuring. Short press the 

button                to exit the mode.

CALCULATIONS

Addition/subtraction

Make a measurement. Short press the button               to select either addition 
or subtraction, and make the 2nd measurement. Calculation result will 
appear in the main line on the display. The next measurements will also be 
added/subtracted to/from the next measuring result.                                                                                                                                        

Area

Short press the button                  once. Symbol                             will appear on the 

display. Laser beam will be on. Short press the button                        to measure 

the 1st side (length). Short press the button                        to measure the 2nd 

side (width). Area (composition of length and width) will be calculated and 

appear in the main line on the display.

Short press the button                   to exit the mode.             

Volume

Short press the button                 twice. Symbol                    will appear on the 

display. Laser beam will be on. Short press the button                     to measure 

the 1st side (length). Short press the button                      to measure the 

2nd side (width). Short press the button                     to measure the 3rd side 

(height). Volume (composition of length, width and height) will be calculated 

and appear in the main line on the display.

Short press the button                      to exit the mode. 

             

Indirect measurement by Pythagoras’ Theorem

Calculation of distance by using 2 additional measurements

Short press the button   

3 times. Symbol               will 

appear on the display. Make 

measurements  of  distance  А 

and  В.  Length  of  distance  С  will 

be calculated and the result will 

appear in the main line. 

Distance В must be perpendicular 

to  distance  С  and  cannot  be 

longer than distance А. 

Short press the button                to exit the mode. 

Calculation of distance by using 3 additional measurements

Distance D can be measured by making 3 additional measurements. 

        

Short press the button                 4 times. Symbol             will appear on the 

display. Laser beam will be on. Make measurements of distances А, В and 

С one by one.

After the last made measurement 

calculation result (distance D) will 

appear in the main line on the 

display. 

Short press the button               to 

exit the mode. 

MEASUREMENT CONDITIONS

Measurement range 

The maximum measurement range is 30 m. At night, at dusk, or if the object 

of measurement is shaded, the measurement range can be increased 

without the use of a reflective plate. Use a reflective plate to increase the 

measurement range during daylight hours, or if the object being measured 

has a poor reflective surface.

Object surface

When  measuring  up  to  colorless  liquids  (e.g.  water),  dust-free  glass, 

polystyrene or similar translucent and glossy surfaces, the measurement 

results may be wrong. When measuring to very dark surfaces, the 

measurement time may increase.

Display

Keyboard

Battery cover 

1

3

4

2

1

2

3

4

5

6

Summary of Contents for Vector 30

Page 1: ...h batteries must be of the same brand with the same charge level Switch on off To switch on the device short press the button The device will switch on and enter single distance measurement mode To sw...

Page 2: ...Expired tools accessories and package should be passed for waste recycle Please send the device to the following address for proper recycle CONDTROL GmbH Wasserburger Strasse 9 84427 Sankt Wolfgang Ge...

Page 3: ...hzeitig ausgewechselt werden Setzen Sie nur Batterien desselben Herstellers und der gleichen Spannung ein Ein Ausschalten Dr cken Sie die Taste um das Produkt einzuschalten und in den Messmodus zu wec...

Page 4: ...hr gebrauchsfaehige Messwerkzeuge getrennt zu sammeln und zu einer Recyclingstelle zu bringen GARANTIE Alle Geraete der CONDTROL GmbH werden vor dem Verlassen der Produktion geprueft und unterliegen d...

Page 5: ...20 690 EN 60825 1 2014 10 Vector 30 0 05 30 1 3 II 620 690 1 30 180 5000 20 70 0 40 IP54 2 1 5 AAA LR03 115 39 19 42 Vector 30 RU 1 1 2 1 3 1 4 1 5 AAA LR03 2 1 2 3 4 1 2 3 4 5 6 203 2 180 2 m in ft 2...

Page 6: ...203 402 301 302 101 102 201 401 10 2002 96 2006 66 24 36 www condtrol ru...

Page 7: ...any do zapobiegania korozji i roz adowywaniu si baterii Wszystkie baterie musz by wymieniane w tym samym czasie Oba akumulatory musz by tej samej marki o tym samym poziomie na adowania W czanie wy cza...

Page 8: ...r nych typ w baterii o r nych poziomach na adowania UTYLIZACJA Przeterminowane narz dzia akcesoria i opakowanie nale y przekaza do recyklingu Odes a urz dzenie na nast puj cy adres w celu prawid oweg...

Reviews: