SONO 3500 CT
Operating Instructions, 07/2019, VI.SH.P2.02
67
Technical data
10
10.1
SONO 3500 CT
Table 10- 1 SONO 3500 CT
Description
Specification
Enclosure design/material
Fiber glass reinforced polyamide in light-gray color
Enclosure
IP67 according to EN 60529 and DIN 40050 (NEMA 4X/6)
Wall mounting kit
Terminal box made of fiber glass reinforced polyamide in light-gray
color with 2 + 2 cable glands (output, supply and transducer ca-
bles) and a stainless steel bracket for wall or pipe mounting
Cable glands
In wall mounting kit:
•
4 x M20 PA plastic cable glands (2 for mains and output cable,
2 for the transducer coaxial cables)
Ambient temperature
-10 °C to +55 °C (14 °F to 131 °F)
1)
Storage temperature
−40 °C to + 85 °C (−40 °F to +185 °F)
Transducer/sensor cables
•
Coaxial cable, impedance 75 Ohm, ∅ app. 6 mm;
•
Cable length: Max. 30 meter between transmitter and trans-
ducer (5 m (16.4 ft), 10 m (32.8 ft), 20 m (65.6 ft), or 30 m (98.4
ft) available)
Mechanical vibration
2 g, 1 to 800 Hz sinusoidal in all directions according to IEC 68-2-6
Power supply
Mains with single battery backup (always store a replacement 3.6
V LiSOCl (Lithium Thionyl Chloride) battery
2)
):
•
87 to 265 V AC (50 to 60 Hz)
Display
•
LCD, 8 digits, additional 2 digits and symbols for status infor-
mation
•
Units: Volume unit: m
3
(default display unit), Flow unit: m
3
/h
(default display unit)
•
Alarm codes (F 1 to F 9) for: path 1 or 2 not measuring, internal
failure, power supply failure, flow overload, pulse output fre-
quency overload, data logger warning
Push button
One push button for toggling between display information
Measuring function
•
0.5 Hz (battery mode)
•
15 Hz (mains-powered)
Communication
•
IrDA on display panel (Modbus RTU protocol)
Содержание SONO 3500 CT
Страница 1: ...Ultrasonic Flowmeter Operating Instructions SONO 3500 CT 07 2019 Edition ...
Страница 2: ......
Страница 8: ...Table of contents 6 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 14: ...Introduction 1 5 Further Information 12 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 38: ...Electrical connection 5 5 Sealing of SONO 3500 CT 36 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 50: ...Commissioning 6 4 Commissioning via PDM 48 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 54: ...Functions 7 4 Hardware key 52 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 64: ...Service and maintenance 8 7 Battery disposal 62 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...