Item
Type
Range
Description [Unit]
Serial_Lower
U32
——
The lower 32 bits of the LiDAR serial number.
Firmware_Patch
U8
——
The patch version of the firmware used by the
connected LiDAR.
Firmware_Minor
U8
——
The minor version of the firmware used by the
connected LiDAR.
Firmware_Major
U8
——
The major version of the firmware used by the
connected LiDAR.
Dropped_Frames
U32
——
The number of times packets were dropped.
Sensor_Status
U8
——
Reports the current status of the LiDAR.
0: Idle
1: Initializing
2: Running
Thread_State
U8
——
Reports the current state of the background
thread.
0: Idle
1: Launching
2: Initializing
3: Running
4: Killing
5: Restarting
Fault Signals
The following table describes signals in the Fault page.
Item
Type
Range
Description [Unit]
Log_Fault_ID
ARRAY[30]U32 0 to
4294967295
List of the 30 most recent active or inactive fault
codes.
Get_Alerts_log_isValid
BOOL
T/F
Indicates that the compliance block received
fault messages from the LiDAR.
Get_Alerts_active_isValid
BOOL
T/F
Indicates that at least one fault from the LiDAR is
currently active.
Warning
BOOL
T/F
Indicates that the Log_Fault_ID list contains at
least one warning-level fault.
T: The list contains at least one warning-level
fault.
F: The list contains no warning-level faults.
Notice
BOOL
T/F
Indicates that the Log_Fault_ID list contains at
least one notice-level fault.
T: The list contains at least one notice-level fault.
F: The list contains no notice-level faults.
Error
BOOL
T/F
Indicates that the Log_Fault_ID list contains at
least one error-level fault.
T: The list contains at least one error-level fault.
F: The list contains no error-level faults.
User Manual
Ouster LiDAR
Inputs, Outputs, and Parameters
36 |
©
Danfoss | March 2023
AQ404281942428en-000103