The image shows the Ouster Interface Box connected to a network smart switch. The switch is also
connected to the XM100 controller. These two cables may not come with the Ouster LiDAR hardware.
Configure the Ethernet Output Using the Controller DHCP Service
Follow these instructions to configure the DHCP service on the controller to allow it to assign IP
addresses to devices connected to it.
Follow the guidelines in
Configure Using the Controller DHCP Service
Ensure that the IP addresses you use are not currently in use on the network.
1. From the top of the application, enter the Outputs page, then the Ethernet page. Do not open the
USBEthernet page.
2. Set Enable to True to enable communication over Ethernet.
3. Set DHCP to 0.
4. Configure the IP Address settings.
a) Modify the Static_IP value to set the IP Address of the controller.
b) Modify the Static_NetMask value to the set the netmask of the network.
c) Modify the Static_Gateway to set the gateway of the network.
d) Modify the Static_GWMetric value to set the IPv4 dateway metric.