6. Turn on both sets of Ouster LiDAR hardware.
7. Connect the first Ouster LiDAR hardware to Port 2 of the network smart switch using a Cat6 Ethernet
cable. Wait for about a minute for the second IP address to be assigned. For example, 192,168,1,102.
8. Connect the second Ouster LiDAR hardware to Port 3 of the network smart switch using a Cat6
Ethernet cable. Wait for about a minute for the third IP address to be assigned. For example,
192,168,1,103.
9. Connect the computer to Port 4 of the network smart switch using an Ethernet cable. Wait for about a
minute for the fourth IP address to be assigned. For example, 192,168,1,104.
10. Verify the IP addresses are assigned as expected.
a) Open a new Microsoft Powershell session.
b) Ping the Ouster LiDAR hardware connected to Port 2 by typing in "ping os-xxxxxxxxx.local", but
replace the x's with the Ouster LiDAR hardware serial number, which is found on the LiDAR's top.
c) Verify the Ouster responds with the correct IP address. For example, 192,168,1,102.
d) Repeat the ping command for the second Ouster, and see it replies with the IP address. For
example, 192,168,1,103.
If the IP addresses did not respond correctly:
1. Go into the GUIDE application and change the Ouster LiDAR compliance block IP address parameters
to match the IP address in the ping response.
2. Download the application again. It is fine to download it to the XM100 through the standard Ethernet
gateway if downloading a second time.
3. Verify the IP addresses are assigned correctly by pinging the Ouster LiDAR hardware again.
User Manual
Ouster LiDAR
Configure Multiple LiDARs
©
Danfoss | March 2023
AQ404281942428en-000103 | 31