Feature Descriptions
•
51
Counter and Timer Control Feature Descriptions
Display Name
Feature & Values
Description
Device
Version
& View
Counter Selector
counterSelector
Selects the counter to configure.
1.00
Expert
DFNC
Counter 1
Counter1 Select counter 1
Counter mode
counterMode
Selects the counter mode. The selected Counter is
either Active or Disabled. When Disabled, the Counter
can be configured.
1.00
Expert
DFNC
Off
Off The selected Counter is Disabled
Active
Active The selected Counter is Enabled
Counter Status
counterStatus
Returns the current state of the counter.
1.00
Expert
DFNC
Counter Idle
CounterIdle The counter is idle.
The counterStartSource feature is set to off.
Counter Trigger Wait
CounterTriggerWait The counter is waiting for a start trigger.
Counter Active
CounterActive The counter is counting for the specified duration.
Counter Completed
CounterCompleted The counter reached the CounterDuration count.
Counter Overflow
CounterOverflow The counter reached its maximum possible count.
Counter Start Source
counterStartSource
Select the counter start source. Counter increments
from 0 to the value of the counterDuration feature.
1.00
Expert
DFNC
Off
Off Counter is stopped.
Exposure Start
ExposureStart Counter starts on the reception of the Exposure Start
event
Exposure End
ExposureEnd Counter starts on the reception of the Exposure End
event.
Readout Start
ReadoutStart Counter starts on the reception of the Readout Start
event.
Readout End
ReadoutEnd Counter starts on the reception of the Readout End
event.
Frame Start
FrameStart Counter starts on the reception of the Frame Start
event.
Valid Frame Trigger
ValidFrameTrigger Counter starts on the reception of the Valid Frame
Trigger.
Rejected Frame Trigger
InvalidFrameTrigger Counter starts on the reception of the Invalid Frame
Trigger.
Line 1
Line1 Counter starts on the specified transitions on CXP or
Line 1 trigger.
Line 2
Line2 Counts the number of transisitions on Line 2 (based
on the counterIncrementaLineActivation feature
setting).
Timer 1 End
Timer1End Counter starts on the reception of the Timer 1 End
event.
Counter 1 End
Counter1End Counter starts on the reception of the Counter 1 End
event.
Counter Start Line
Activation
counterStartLineActivation
Selects the activation mode of the input line trigger
which starts the counter. This is only applicable when
the counterStartSource feature selects a physical
Line.
1.00
Expert
DFNC
Rising Edge
RisingEdge Starts counting on rising edge of the selected Line.
Falling Edge
FallingEdge Starts counting on falling edge of the selected Line.
Any Edge
AnyEdge Starts counting on the falling or rising edge of the
selected Line.
Содержание Genie Nano-CXP
Страница 17: ...Genie Nano CXP Series Nano CXP Specifications 15 Quantum Efficiency Curves ...
Страница 132: ...130 Additional Reference Information Genie Nano CXP Series Cable Assembly G3 AIOC BLUNT1M ...
Страница 133: ...Genie Nano CXP Series Additional Reference Information 131 Cable Assembly G3 AIOC BLUNT2M ...
Страница 134: ...132 Additional Reference Information Genie Nano CXP Series ...
Страница 135: ...Genie Nano CXP Series Additional Reference Information 133 Cable Assembly G3 AIOC BRKOUT2M ...
Страница 136: ...134 Additional Reference Information Genie Nano CXP Series ...
Страница 137: ...Genie Nano CXP Series Additional Reference Information 135 Nano Generic Power Supply with no I O ...
Страница 139: ...Genie Nano CXP Series Additional Reference Information 137 Cable Assembly Right Angle I O to Euro Block ...