![Dalsa Genie Nano-CXP Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/dalsa/genie-nano-cxp/genie-nano-cxp_user-manual_504434046.webp)
44
•
Feature Descriptions
Genie Nano-
CXP Series™
Output Line Pulse Signal
Activation
outputLinePulseActivation
Specifies the input line activation mode to trigger the
OutputLine pulse.
1.02
Beginner
DFNC
Rising Edge
RisingEdge
Specifies that the trigger is considered valid on the
rising edge of the source signal.
Falling Edge
FallingEdge
Specifies that the trigger is considered valid on the
falling edge of the source signal.
Any Edge
AnyEdge
Specifies that the trigger is considered valid on the
falling or rising edge of the source signal.
Output Line Pulse Delay
outputLinePulseDelay
Sets the delay (in µs) before the output line pulse
signal. Applicable for the OutputLineSource feature.
1.02
Beginner
DFNC
Output Line Pulse Duration
outputLinePulseDuration
Sets the width (duration) of the output line pulse in
microseconds.
1.02
Beginner
DFNC
outputLineValue
Sets the output state of the selected Line if the
outputLineSoftwareLatchControl = OFF.
OutputLineSource must be SoftwareControlled.
1.02
Beginner
DFNC
Active
Active
Sets the Output circuit to close
Inactive
Inactive
Sets the Output circuit to open
Line Status All
LineStatusAll
Returns the current status of all available line signals, at
time of polling, in a single bitfield. The order is Line1,
Line2, Line3, ...
1.00
Expert
Line Format
LineFormat
Specify the current electrical format of the selected
physical input or output.
1.00
Invisible
CXP
CxP
The line accepts CXP Trigger packets.
Opto-Coupled
OptoCoupled
The line is opto-coupled.
Line Mode
LineMode
Reports if the physical Line is an Input or Output signal..
1.00
Invisible
Input
Input
The line is an input line.
Output
Output
The line is an output line.
Input Line Detection Level
lineDetectionLevel
Specifies the voltage threshold required to recognize a
signal transition on an input line.
1.00
Invisible
DFNC
Threshold for TTL
Threshold_for_TTL
A signal below 0.8V will be detected as a Logical LOW
and a signal greater than 2.4V will be detected as a
Logical HIGH on the selected input line.
Содержание Genie Nano-CXP
Страница 17: ...Genie Nano CXP Series Nano CXP Specifications 15 Quantum Efficiency Curves ...
Страница 132: ...130 Additional Reference Information Genie Nano CXP Series Cable Assembly G3 AIOC BLUNT1M ...
Страница 133: ...Genie Nano CXP Series Additional Reference Information 131 Cable Assembly G3 AIOC BLUNT2M ...
Страница 134: ...132 Additional Reference Information Genie Nano CXP Series ...
Страница 135: ...Genie Nano CXP Series Additional Reference Information 133 Cable Assembly G3 AIOC BRKOUT2M ...
Страница 136: ...134 Additional Reference Information Genie Nano CXP Series ...
Страница 137: ...Genie Nano CXP Series Additional Reference Information 135 Nano Generic Power Supply with no I O ...
Страница 139: ...Genie Nano CXP Series Additional Reference Information 137 Cable Assembly Right Angle I O to Euro Block ...