42
•
Feature Descriptions
Genie Nano-
CXP Series™
I/O Control Feature Descriptions
Display Name
Feature & Values
Description
Device
Version
& View
Trigger Selector
TriggerSelector
Selects which type of trigger to configure with the
various Trigger features.
1.00
Beginner
Single Frame Trigger(Start)
FrameStart
Selects a trigger starting the capture of a single frame.
Frame size is determined by image format feature
“Height”.
MultiFrame Trigger(Start)
FrameBurstStart
Selects a trigger to capture multiple frames. The
number of frames is specified by the
“triggerFrameCount” feature.
Trigger Mode
TriggerMode
Controls the enable state of the selected trigger.
1.00
Beginner
Off
Off
The selected trigger is turned off.
On
On
The selected trigger is turned active.
Trigger Frames Count
triggerFrameCount
Sets the total number of frames to acquire when a valid
trigger is received. This feature is available when Trigger
Selector = MultiFrame Trigger(Start).
1.00
DFNC
Beginner
Software Trigger
TriggerSoftware
Generate a software command internal trigger
immediately no matter what the TriggerSource feature
is set to.
1.00
Beginner
Trigger Source
TriggerSource
Specifies the internal signal or physical input line to use
as the trigger source. The selected trigger must have its
TriggerMode set to ON.
1.00
Beginner
CXP Trigger
CXP
Select CXP trigger (and associated I/O control block) to
use as the external trigger source. See LineSelector
feature for complete list.
Software
Software
The trigger command source is only generated by
software using the Trigger Software command.
Line 1
Line1
Select Line 1 (and associated I/O control block) to use
as the external trigger source. See LineSelector feature
for complete list.
Line 2
Line 2
Select Line 2 (and associated I/O control block) to use
as the external trigger source. See LineSelector feature
for complete list.
Timer1End Event
Timer1End
Select the TimerEnd Event as the internal trigger source.
Counter1End Event
Counter1End
Select the CounterEnd Event as the internal trigger
source.
Trigger Input Line Activation
TriggerActivation
Select the activation mode for the selected Input Line
trigger source. This is applicable only for external line
inputs.
1.00
Beginner
Rising Edge
RisingEdge
The trigger is considered valid on the rising edge of the
line source signal (after any processing by the line
inverter module).
Falling Edge
FallingEdge
The trigger is considered valid on the falling edge of the
line source signal (after any processing by the line
inverter module).
Level High
LevelHigh
The trigger is considered valid on the high level of the
line source signal. (OnSemi models only)
Level Low
LevelLow
The trigger is considered valid on the low level of the
line source signal. (OnSemi models only)
Trigger Delay
TriggerDelay
Specifies the delay in microseconds to apply after
receiving the trigger and before activating the
triggerEvent.
1.00
Beginner
Содержание Genie Nano-CXP
Страница 17: ...Genie Nano CXP Series Nano CXP Specifications 15 Quantum Efficiency Curves ...
Страница 132: ...130 Additional Reference Information Genie Nano CXP Series Cable Assembly G3 AIOC BLUNT1M ...
Страница 133: ...Genie Nano CXP Series Additional Reference Information 131 Cable Assembly G3 AIOC BLUNT2M ...
Страница 134: ...132 Additional Reference Information Genie Nano CXP Series ...
Страница 135: ...Genie Nano CXP Series Additional Reference Information 133 Cable Assembly G3 AIOC BRKOUT2M ...
Страница 136: ...134 Additional Reference Information Genie Nano CXP Series ...
Страница 137: ...Genie Nano CXP Series Additional Reference Information 135 Nano Generic Power Supply with no I O ...
Страница 139: ...Genie Nano CXP Series Additional Reference Information 137 Cable Assembly Right Angle I O to Euro Block ...