46
•
Feature Descriptions
Genie Nano-
CXP Series™
Trigger Mode Details
Nano-CXP image exposures are initiated by an event. The trigger event is either the camera
’
s
programmable internal clock used in free running mode, an external input to the controlling frame
grabber used for synchronizing exposures to external triggers, or a programmed function call
message by the controlling computer. These triggering modes are described below.
•
Free running (Trigger Mode=Off)
: The Nano free-running mode has programmable internal
timers for frame rate and exposure period. Frame rate minimums, maximums, and increments
supported are sensor specific. Maximum frame rates are dependent on the required exposure.
•
Trigger Source (Trigger Mode=On)
: Exposures are controlled by an external trigger signal
where the specific input line is selected by the
Trigger Source
feature.
Trigger Source Types (Trigger Mode=On)
•
Trigger Source=CXP
: The CoaXPress trigger (controlled by the frame grabber) is used as the
external trigger control.
•
Trigger Source=Software
: An exposure trigger is sent as a software command. Software
triggers cannot be considered time accurate due to computer latency and sequential command
jitter. But a software trigger is more responsive than calling a single-frame acquisition since the
latter must validate the acquisition parameters and modify on-board buffer allocation if the
buffer size has changed since the last acquisition.
•
Trigger Source=Timer1End Event
: The Timer1 End Event is used as the internal trigger
source. Refer to
for information on those features.
•
Trigger Source=Counter1End Event
: The Counter1 End Event is used as the internal trigger
source.
Содержание Genie Nano-CXP
Страница 17: ...Genie Nano CXP Series Nano CXP Specifications 15 Quantum Efficiency Curves ...
Страница 132: ...130 Additional Reference Information Genie Nano CXP Series Cable Assembly G3 AIOC BLUNT1M ...
Страница 133: ...Genie Nano CXP Series Additional Reference Information 131 Cable Assembly G3 AIOC BLUNT2M ...
Страница 134: ...132 Additional Reference Information Genie Nano CXP Series ...
Страница 135: ...Genie Nano CXP Series Additional Reference Information 133 Cable Assembly G3 AIOC BRKOUT2M ...
Страница 136: ...134 Additional Reference Information Genie Nano CXP Series ...
Страница 137: ...Genie Nano CXP Series Additional Reference Information 135 Nano Generic Power Supply with no I O ...
Страница 139: ...Genie Nano CXP Series Additional Reference Information 137 Cable Assembly Right Angle I O to Euro Block ...