48
•
Feature Descriptions
Genie Nano-
CXP Series™
•
TriggerOverlap=ReadOut
•
Trigger is accepted at the beginning of the frame Readout. The
“End of Exposure to Start of
Readout” time is sensor dependent.
Diagram Conditions:
•
TriggerMode=On
•
ExposureMode=Timed
•
TriggerActivation=RisingEdge
•
TriggerDelay=0
•
TriggerSelector=FrameStart
•
ExposureAlignment=Synchronous
•
Trigger to Exposure start has a delay which includes the sensor readout time plus a
minimum of 62µs. An exposure always starts after the readout of the previous frame.
Trigger Input
Trigger Exclusion Period
Exposure 1
Readout 1
Frame 1 Active period
Exposure 2
Readout 2
Frame 2 Active period
Frame Exposure
Frame Readout
TriggerOverlap=Readout
Trigger Exclusion Period
End of Exposure
to Start of Readout
End of Exposure
to Start of Readout
Содержание Genie Nano-CXP
Страница 17: ...Genie Nano CXP Series Nano CXP Specifications 15 Quantum Efficiency Curves ...
Страница 132: ...130 Additional Reference Information Genie Nano CXP Series Cable Assembly G3 AIOC BLUNT1M ...
Страница 133: ...Genie Nano CXP Series Additional Reference Information 131 Cable Assembly G3 AIOC BLUNT2M ...
Страница 134: ...132 Additional Reference Information Genie Nano CXP Series ...
Страница 135: ...Genie Nano CXP Series Additional Reference Information 133 Cable Assembly G3 AIOC BRKOUT2M ...
Страница 136: ...134 Additional Reference Information Genie Nano CXP Series ...
Страница 137: ...Genie Nano CXP Series Additional Reference Information 135 Nano Generic Power Supply with no I O ...
Страница 139: ...Genie Nano CXP Series Additional Reference Information 137 Cable Assembly Right Angle I O to Euro Block ...