Option List
SiUS34-801A_b
518
Appendix
4. Option List
4.1
Option List of Controllers
Optional Accessories of Operation Control System
C:3D043022D
Notes:
1. Installation box (No.4) is necessary for each adaptor marked .
2. Electrical box (5-1/6-1) is required for controller (No. 5/6).
Building management system
Notes:
1. BACnet
®
is a registered trademark of American Society of Heating, Refrigerating and Air-
Conditioning Engineers (ASHRAE).
2. LonWorks
®
is a registered trade mark of Echelon Corporation.
No.
Type
Item
FXFQ~M7VJU FXZQ-MVJU FXSQ~MVJU FXMQ~MVJU FXAQ~MVJU
FXLQ~MVJU
FXNQ~MVJU
FXHQ~MVJU FXDQ~MVJU
1
Remote controller
Wireless
BRC7C812
—
BRC4C82
BRC7E818
—
BRC7E83
BRC4C82
Wired
BRC1C71
BRC1D71
2
Set back time clock
BRC15A71
3
Remote sensor
KRCS01-1
4
Installation box for adaptor PCB
KRP1B98
KRP1BA101
—
KRP1C93
KRP1B101
5
Central remote controller
DCS302C71
5-1 Electrical box
KJB311A
6
Unified on/off controller
DCS301C71
6-1 Electrical box
KJB212A
7
Schedule timer
DST301B61
8
External control adaptor for outdoor unit
DTA104A62
DTA104A61
—
DTA104A6
1
DTA104A
62
DTA104A
53
9
D3-NET Expander adaptor
DTA109A51
10
Simplified remote controller
—
BRC2A71
—
BRC2A71
—
BRC2A71
11
Adaptor for wiring
KRP1B72
KRP1B57
KRP1B71
KRP1B73
—
12
Wiring adaptor for electrical appendices (2)
KRP4A73
KRP4A53
KRP4A71
KRP4A72
KRP4A74
Part name
Model No.
Function
intellig
ent Touch
Con
tro
ller
basic
Hardware
intelligent
Touch
Controller
DCS601C71
• Air-Conditioning management system that can be controlled by a compact all-in-one unit.
Option
Software
Web
DCS004A71
• Monitors and controls the air conditioning system using the Internet and Web browser
application on a PC.
Communicat
ion
Li
ne
∗
2 Interface for use in BACnet
®
DMS502A71
Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-
conditioning systems through BACnet
®
communications.
Optional DIII board
DAM411A1
Expansion kit, installed on DMS502A71, to provide 3 more DIII-NET communication ports. Not
usable independently.
Optional Di board
DAM412A1
Expansion kit, installed on DMS502A71, to provide 16 more wattmeter pulse input points. Not
usable independently.
∗
3 Interface for use in L
ON
W
ORKS
®
DMS504B71
Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-
conditioning systems through L
ON
W
ORKS
®
communication.
Co
nta
c
t/
A
na
log
sig
nal
Unification adaptor for computerized
control
DCS302A72
Interface between the central monitoring board and central control units
Wiring adaptor for electrical
appendices (2)
KRP4A71-74
To control the group of indoor units collectively, which are connected by the transmission wiring
of remote controller.
External control adaptor for outdoor
unit (Must be installed on indoor units.)
DTA104A53, 61,
62
Cooling/Heating mode changeover. Demand control and Low noise control are available
between the multiple outdoor units.
Содержание VRV III
Страница 15: ...SiUS34 801A_b xiv ...
Страница 23: ...Model Selection SiUS34 801A_b 8 General Information ...
Страница 133: ...Field Settings SiUS34 801A_b 118 VRVIII R 410A Heat Pump 60Hz ...
Страница 254: ...SiUS34 801A_b Test Operation VRVIII R 410A Heat Recovery 60Hz 239 R 410A Label R 410A Label ...
Страница 329: ...Field Setting SiUS34 801A_b 314 Indoor Unit ...
Страница 340: ...SiUS34 801A_b Troubleshooting by Remote Controller Troubleshooting 325 ...
Страница 490: ...SiUS34 801A_b Piping Diagrams Appendix 475 Heat Pump 230V RXYQ72 96 120PTJU 3D058636A ...
Страница 491: ...Piping Diagrams SiUS34 801A_b 476 Appendix Heat Pump 230V RXYQ144PTJU 3D058640 ...
Страница 492: ...SiUS34 801A_b Piping Diagrams Appendix 477 Heat Recovery 460V REYQ72 96 120PYDN 3D058639A ...
Страница 493: ...Piping Diagrams SiUS34 801A_b 478 Appendix Heat Recovery 460V REMQ72PYDN 3D058637A ...
Страница 494: ...SiUS34 801A_b Piping Diagrams Appendix 479 Heat Recovery 460V REMQ96 120PYDN 3D058638A ...
Страница 495: ...Piping Diagrams SiUS34 801A_b 480 Appendix Heat Recovery 230V REYQ72 96 120PTJU 3D058639A ...
Страница 496: ...SiUS34 801A_b Piping Diagrams Appendix 481 Heat Recovery 230V REYQ144PTJU 3D058640 ...
Страница 497: ...Piping Diagrams SiUS34 801A_b 482 Appendix Heat Recovery 230V REMQ72PTJU 3D058637A ...
Страница 498: ...SiUS34 801A_b Piping Diagrams Appendix 483 Heat Recovery 230V REMQ96 120PTJU 3D058638A ...
Страница 501: ...Piping Diagrams SiUS34 801A_b 486 Appendix 1 3 BS Unit 4D057985A ...
Страница 537: ...Piping Installation Point SiUS34 801A_b 522 Appendix ...
Страница 543: ...Pressure Sensor SiUS34 801A_b 528 Appendix ...
Страница 559: ...Precautions for New Refrigerant R 410A SiUS34 801A_b 544 Precautions for New Refrigerant R 410A ...
Страница 563: ...SiUS34 801A_b iv Index ...