DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
418
Figure 11-109 sFlow Sampler Settings Window
The fields that can be configured are described below:
Parameter
Description
Unit
Select the Switch unit that will be used for this configuration here.
From Port - To Port
Select the appropriate port range used for the configuration here.
Instance
Enter the instance index number if multiple samplers are associated with one
interface. The valid range is from 1 to 65535.
Receiver
Enter the receiver index for this sampler. If not specified, the value is 0. This
value must be between 1 and 4.
Mode
Select the mode here. Options to choose from are
Inbound
and
Outbound
.
•
Selecting
Inbound
specifies to sample ingress packets. This is the default
direction of a sampler.
•
Selecting
Outbound
specifies to sample egress packets.
Sampling Rate
Enter packet sampling rate here. This value must be between 0 and 65536.
Entering 0 will disable this function. If not specified, the default value is 0.
Max Header Size
Enter the maximum number of bytes that should be copied from sampled
packets. This value must be between 18 and 256 bytes. By default, this value is
128 bytes.
Click the
Apply
button to accept the changes made.
Click the
Delete
button to remove the specified entry.
Enter a page number and click the
Go
button to navigate to a specific page when multiple pages exist.
sFlow Poller Settings
This window is used to display and configure the sFlow poller settings.
To view the following window, click
Monitoring > sFlow > sFlow Poller Settings