DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
391
Cable Diagnostics
The cable diagnostics feature is designed primarily for administrators or customer service representatives to verify and
test copper cables; it can rapidly determine the quality of the cables and the types of error.
To view the following window, click
OAM > Cable Diagnostics
, as shown below:
Figure 10-221 Cable Diagnostics Window
The fields that can be configured are described below:
Parameter
Description
Unit
Select the Switch unit that will be used for this configuration here.
From Port - To Port
Select the appropriate port range used for the configuration here.
Click the
Test
button to test the specific port.
Click the
Clear
button to clear all the information for the specific port.
Click the
Clear All
button to clear all the information in this table.
NOTE: Cable diagnostic function limitations. Cable length detection is only supported on physical
port interface.
NOTE: The maximum cable diagnosis length is 120 meters.
NOTE: The deviation of cable length detection is about 10 meters for GE ports.
Fault messages:
•
Unknown
- The diagnosis result contains open, short or cross talk status. Any one of the status be detected,
switch will display unknow error message.
•
NA
- No cable was found, maybe it's because cable is out of diagnosis specification or the quality is too bad.
Содержание DGS-3130 Series
Страница 1: ......