DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
384
After clicking the
Edit DM
button, the following page will appear.
Figure 10-10 CFM Settings (Add MA, Add MEP, Edit DM) Window
The fields that can be configured in
CFM DM Settings
are described below:
Parameter
Description
State
Select to enable or disable the ITU Y.1731 frame Delay Measurement (DM)
feature here. When the administrative state of frame delay measurement
function is enabled on an MEP, the MEP will be enabled to generate timestamp
information, and can reply DMR messages when receiving DMM messages.
Click the
Apply
button to accept the changes made.
The fields that can be configured in
CFM DM Test
are described below:
Parameter
Description
MAC Address
Enter the MAC address for the DM test here.
Period Interval
Select the period interval time here. This specifies the transmitting period of the
DDM message and diagnostic interval. Options to choose from are:
•
100ms-1sec
- The transmission period is 100 milliseconds and the
diagnostic interval is 1 second.
•
1sec-10sec
- The transmission period is 1 second and the diagnostic
interval is 10 seconds. This is the default value.
•
10sec-1min
- The transmission period is 10 seconds and the diagnostic
interval is 1 minute.
Percentile
Enter the percentile value here. This specifies the percentile of Frame Delay
(FD) and Frame Delay Variation (FDV) measurement. The range is from 0 to
100. The default value is 75.
PDU Priority
Select the PDU priority value here. The range is from 0 to 7. This specifies the
802.1p priority to be set in the DMM messages transmitted by the MEP. The
default value is the PDU priority of the MEP.