DGS-3130 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
403
Figure 10-282 DDM RX Power Threshold Settings Window
The fields that can be configured are described below:
Parameter
Description
Unit
Select the Switch unit that will be used for this configuration here.
Port
Select the port used for the configuration here.
Action
Select the action that will be taken here. Options to choose from are
Add
and
Delete
.
Type
Select the type of RX power threshold. Options to choose from are
Low Alarm,
Low Warning, High Alarm
, and
High Warning
.
Power Unit
Select the power unit here. Options to choose from are
mW
and
dBm
.
Value
Enter the threshold value either in
mW
or
dBm
here.
•
When selecting
mW
in the
Power Unit
drop-down list, this value must be
between 0 and 6.5535.
•
When selecting
dBm
in the
Power Unit
drop-down list, this value must be
between -40 and 8.1647.
Click the
Apply
button to accept the changes made.
DDM Status Table
This window is used to display the current operating digital diagnostic monitoring parameters and their values on the
SFP/SFP+ module for specified ports.
To view the following window, click
OAM > DDM > DDM Status Table
, as shown below:
Figure 10-293 DDM Status Table Window