Example Projects
Figure 5-42. Thermal Manager Flowchart
In this example, the LCD displays status information about thermal management system across
three screens. You can cycle through the status screens by pressing SW1 on the CY8CKIT-001 DVK
or SW2 on the CY8CKIT-030 DVK. The three screens are:
■
Screen 1 - Zone 1 Summary
This screen displays the current status of Zone 1. Line 1 displays the zone number, current com-
posite zone temperature, and the zone temperature calculation algorithm used. Line 2 displays
the desired fan speed and the actual fan speed for Zone 1.
Figure 5-43. Zone 1 Summary
■
Screen 2 - Zone 2 Summary
This screen displays the current status of Zone 2. Line 1 displays the zone number, current com-
posite zone temperature, and the zone temperature calculation algorithm used. Line 2 displays
the desired fan speed and the actual fan speed for Zone 2.
Calculate Fan 3 and Fan 4
Speeds based on Thermal
Profiles
Calculate Zone1 and
Zone 2 Temperatures
Start
500 ms
Timer
Expired?
Y
Initialize Components and
Variables
Fan Speed
Needs
Change?
Set Desired Fan Speeds
Launch Next Temperature
Measurement
Handle Button Presses
and Update LCD
N
N
Y
Z 1 : T
1 6
W E I G H T E D
F 3 : 4 5 0 0
A 3 : 4 5 1 5
=