Example Projects
3. Connect a 20 mV full scale differential signal to P0_0 (+) and P0_1 (–).
4. Connect a 100 mV full scale differential signal to P1_6 (+) and P1_7 (–).
5. Set the system to run at 5 V using SW 3; set J7 VDD DIG and J6 VDD ANLG to VDD = 5 V.
6. Ensure that the LCD included with the CY8CKIT-001 PSoC DVK is attached and the LCD power
jumper (J12) is in the ON position.
7. In the CY8CKIT-025 EBK, choose appropriate jumper settings for internal sensors; see the
5.3.2.2
Run Sequenced ADC Example Firmware
5.3.2.2.1
CY8CKIT-030 PSoC 3 DVK
The steps to run the example firmware on CY8CKIT-030 are:
1. Attach a USB cable from the PC to the PSoC 3 DVK program/debug USB port (use J1, the USB
connector closest to the corner of the board).
2. Open the SequencedADC_030_050 project using PSoC Creator and select
Debug > Program
to program the PSoC.
3. Detach the USB cable and connect hardware according to
Hardware Connections on page 52
4. Plug at 12 V wall-wart into the J4 barrel jack connector.
5. Press the
Reset
(SW1) button on the PSoC 3 DVK to run the newly programmed firmware
image.
6. On reset, the LCD displays the RTD temperature, which is the first item in the user selectable
menu.
7. Press CapSense button
P5_5
to scroll up the menu and
P5_6
to scroll down the menu.