12. MONITORING FUNCTIONS
12.1 Current Conditions
This menu displays the current reading of
the controller’s inputs and outputs. Refer
to the installation chapter to activate the
various probes and outputs.
This menu is automatically selected after
4 minutes of inactivity.
Select
1. Current Conditions
12.2 Individual Temperature Probe Readings
This menu gives the current reading of each
individual temperature probe as well as the
minimum and maximum readings of each
probe for the past 7 days. Refer to the
installation chapter to activate these probes.
Select
2. History
2. Individual Probe Temperature
• Choose the desired probe. The se-
lected probe’s current temperature
and history are displayed.
12.3 History
The history menus allow to visualize the evolution of the controller’s input readings
and of some other controller function. The readings are stored into the history menus
every day at midnight and are reset when a new batch starts.
Main Menu
1.
Current conditions
2.
History
3.
Animal Age & Mortality
4.
Set Point
5.
Minimum Ventilation
6.
Inlet Setup
7.
Light Settings
8.
Start / Stop Temperature
9.
Advanced Settings
10.
Select Program
11.
Alarm Log
12.
Controller Setup
Submenu: Press Enter
Press to Select an Item
Current Conditions
Running Program :
Program 1
Animal Age
5 days
Set Point
70.0 °F
Average Room Temperature
68.0 °F
Minimum Room Temperature
67.5 °F
Maximum Room Temperature
68.5 °F
Probe 1
67.0 °F
Probe 2
69.0 °F
(...)
Probe 8
68.0 °F
Outside Temperature
74.2 °F
Room Relative Humidity
30 %
Minimum Room RH
24 %
Maximum Room RH
32 %
Static Pressure
.02 WC
Total Water consump.
0 gal
Light Intensity
80 %
Tunnel Curtain 1
Off
Tunnel Curtain 2
Off
Inlet 1 Opening
20 %
Inlet 2 Opening
15 %
(...)
Inlet 10 Opening
10 %
Exit: Press Back
Submenu: Press Enter
Press To Select an Item
Main Menu
1.
Current conditions
2.
History
3.
Animal Age & Mortality
4.
Desired House Temperature
5.
Minimum Ventilation Timer
6.
Static Pressure Settings
7.
Light Settings
8.
Start / Stop Temperature
9.
Advanced Settings
10.
Select Program
11.
Alarm Log
12.
Setup
Submenu: Press Enter
Press
to Select an Item
History
1.
Average Room Temperature
2.
Individual Probe Temperature
3.
Outside Temperature
4.
Relative Humidity
5.
Static Pressure
6.
Water Consumption
7.
Mortality
8.
Culled
9.
Heater Run Time
Exit: Press Back
Submenu: Press Enter
Press
to Select an Item
Individual Probe Temperature 7 days
Display
Probe 1
Temperature 77.0 °F
Date Minimum Maximum
July 19 2003 00:34 74.0 12:34 80.2
July 18 2003 02:19 73.4 19:58 71.3
July 17 2003 01:28 72.0 14:34 82.1
July 16 2003 22:21 72.5 12:12 82.2
July 15 2003 08:34 73.3 12:14 79.3
July 14 2003 01:14 75.1 16:32 79.2
July 13 2003 04:52 73.3 13:28 80.7
July 12 2003 05:39 74.2 15:33 79.2
Exit: Press Back