30
EXPERT 64EU rev.03
EXPERT 64EU
Select
12. Controller Setup
7. Probe Assignment*
* Only accessible from the installer mode (s. 4.2).
• Select the desired assignment menu:
Room Temperature:
Select the probes used to deter-
mine the average room temperature
reading.
Heaters:
Assign the probes separately for
each regular and Hi Fire heating
stage.
0-10V Output:
Assign the probes separately for each 0-10V output. Only the outputs that are
used as additional independent ventilation stages or that are used to operate
heating devices are displayed.
Tunnel Curtain:
Select the probes that are used to define the average room temperature when
the controller is in tunnel ventilation mode.
• Put a check mark " " to assign a probe or a dot line
"- - -"
to remove the
assignment.
Main Menu
12.
Controller Setup
Controller Setup
7.
Probe Assignment
8.
Version
9.
Test Mode
Submenu: Press Enter
Press
to Select an Item
Probe Assignment
1.
Room Temperature
2.
Heaters
3.
0-10V Output 1
4.
0-10V Output 2
5.
0-10V Output 3
6.
0-10V Output 4
Exit: Press Back
Submenu: Press Enter
Press to Select an Item
Room Temperature Probe Assignment
1
2
3
4
5
6
7
8
--- --- ---
Exit: Press Back
Change: Press Modify
Press to Select an Item