43
EXPERT 64EU rev.03
EXPERT 64EU
II. If the relay selection changes over time (10 Steps):
The following procedure shows how to make the relay selection separately for each
step of the curve.
Note that the relay selection can only be modified while the curve
is disabled
(refer to sec. 6.1.5.4 to disable the curve).
Select
5. Minimum Ventilation
4. Fan Relay Assignment (10 steps)*
* Only accessible if the “Change Fan Relays with Age”
function enabled in section 6.1.5.1.
This menu allows to select fan relays
that are used during the minimum ven-
tilation cycles separately for each step
of the curve. A curve is composed of
10 steps. The user indicates which re-
lays are used for each step of the curve.
• Select the fan relays as follows:
According to Age:
Select a curve step. The relay selection that is displayed is linked with this
curve step. Refer to the next section to define the animal age corresponding to
each step of the curve.
-
If the fan selection alternates during the minimum ventilation cycles:
Select the bank of fan relays that successively alternate during the cycles. This
relay selection must be done separately for each step of the curve.
-
If the fan selection does not alternate during the minimum ventilation cycles:
Select the fan relays that are simultaneously enabled during the cycles. This
relay selection must be done separately for each step of the curve.
• Refer to the following section to enable/disable the minimum ventilation curve
and to set the animal age that corresponds to each step of the curve.
Main Menu
5.
Minimum Ventilation
6.
Inlet Setup
7.
Light Settings
8.
Start / Stop Temperature
9.
Advanced Settings
10.
Select Program
11.
Alarm Log
12.
Controller Setup
Submenu: Press Enter
Press
to Select an Item
Minimum Ventilation
4.
Fan Relay Assignment (10Steps)
5.
Options
Minimum Ventilation Fan Relays
According to Age >
Step 1
1
2 3 4 5 6 7 8
--- --- --- --- --- --- --- ---
9
10
11
12
13
14
15
16
--- --- --- --- --- --- --- ---
17
18
19
20
21
22
23
24
--- --- --- --- --- --- --- ---
25
26
27
28
29
30
31
32
--- --- --- --- --- --- --- ---
Exit: Press Back
Change: Press Modify
Press
to Select an Item
Содержание Integra EXPERT 64EU
Страница 1: ...EXPERT 64EU Temperature Controller USER S MANUAL...
Страница 2: ......
Страница 100: ......
Страница 101: ......
Страница 102: ...M 890 00000 rev 03 REV 02...