22
317961000
3. Remove plug from drop-in refrigeration assembly platform water fill hole.
4. Using a flashlight, inspect ice water bath and ice bank for cleanliness. Ice water bath should be clear and
ice bank free of foreign particles.
5. If cleaning of water tank is necessary, refer to CLEANING WATER TANK in this section.
6. Fill water tank with clean water to top of stainless steel coils located inside tank. USE
LOW-MINERAL-CONTENT WATER WHERE A LOCAL WATER PROBLEM EXISTS.
7. Install plug in water fill hole.
8. Install Unit hood and secure with one screw.
9. Place Unit POWER SWITCH in ‘‘ON’’ position.
CLEANING WATER TANK
(see Figure 5)
1. Place Unit POWER SWITCH in ‘‘OFF’’ position.
2. Extend water tank drain hose to drip tray (if connected to a permanent drain) or waste container. Remove
plug from end of drain hose and allow water tank to drain.
3. Remove Unit hood by removing one screw on top of hood, then lift hood straight up off Unit.
4. Unplug drop-in refrigeration assembly power cord from Unit power cord and electric dispensing valves
transformer power cord socket connector from Unit wiring harness mating male connector.
5. Lift drop-in refrigeration assembly up and out of Unit.
CAUTION: Never use an ice pick or other instrument to remove ice from drop-in
refrigeration assembly evaporator coils. Such practice can result in punctured refrigeration
circuit.
6. Allow ice bank to melt. Hot water may be used to speed melting.
7. Use fiber brush and carefully clean mineral deposit build-up from agitator motor shaft and ice bank sensor
wires.
8. Wash inside of water tank and drop-in refrigeration assembly evaporator coils, then rinse with clean water.
9. Install plug in end of water tank drain hose.
10. Install drop-in refrigeration assembly in Unit by reversing removal procedure.
11. Remove water fill hole plug from drop-in refrigeration assembly platform.
12. Fill water tank with clean water to top of stainless steel coils located inside tank. USE
LOW-MINERAL-CONTENT WATER WHERE A LOCAL WATER PROBLEM EXISTS.
13. Install plug in water fill hole.
14. Install hood on Unit and secure with one screw.
15. Place Unit POWER SWITCH in ‘‘ON’’ position.
CLEANING AND SANITIZING
DAILY CLEANING OF UNIT
1. Remove cup rest from the drip tray.
Содержание SPIRIT
Страница 6: ......
Страница 7: ...2 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 11: ...6 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 17: ...12 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 21: ...16 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 40: ...35 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...