1. Out back of Unit base - Place Unit in location on countertop. Route Unit inlet supply lines, power cord, drip
tray drain hose, and water tank drain hose out back of Unit base. Area around lines coming out of the Unit
base must be closed and sealed.
Out hole cut in countertop under Unit - Place Unit in location on countertop with its drip tray edge flush with
countertop front edge. Mark Unit center line on edge of countertop, then move Unit off to one side. Starting
at Unit center line mark on edge of countertop, measure back 17-inches for location of hole to be cut in
countertop. Cut three-inch diameter hole in countertop. Place Unit in position over hole. Route Unit inlet
supply lines, power cord, drip tray drain hose, and water tank drain hose down through hole in countertop.
2. To comply with National Sanitation Foundation (NSF) requirements, Unit base must be sealed to the
countertop and all access holes to inside of trhe Unit base must be closed and sealed. Proceed as follows
to seal the Unit base.
NOTE: An alternate arrangement to avoid sealing Unit base to countertop would be to install the 4-inch
Leg Kit.
A.
Tilt Unit up to expose bottom of base.
B.
Liberally apply silastic sealant such as Dow Corning RTV 731 or equivalent on base bottom edges.
NOTE: Do not move Unit after positioning or seal from Unit base to countertop will be broken.
C.
Lower Unit into operating position on countertop to complete seal from Unit base to countertop.
D.
Apply additional sealant around bottom of Unit base. Seal must have a minimum radius of 1/2-inch to
prevent crevices and to insure a complete seal.
E.
All access holes to inside of the Unit base must be closed and sealed.
FILL WATER TANK AND START REFRIGERATION SYSTEM
(see Figure 5)
1. Make sure plug in water tank drain hose is secure.
NOTE: Use low-mineral-content water where a local water problem exists.
2. Remove plug from drop-in refrigeration assembly platform water fill hole. Fill water tank with clean water to
top of stainless steel coils located in coil basket. USE LOW-MINERAL-CONTENT WATER WHERE A
LOCAL WATER PROBLEM EXISTS.
3. Install plug in water fill hole.
4. Make sure Unit POWER SWITCH (located on side of Unit) is in ‘‘OFF’’ position.
WARNING: The Unit must be electrically grounded to avoid possible fatal electrical shock
or serious injury to the operator. The Unit power cord is equipped with a three-prong plug.
If a three-hole (grounded) electrical outlet is not available, use an approved method to
ground the Unit.
5. Plug Unit power cord into a properly grounded electrical outlet.
6. Place Unit POWER SWITCH IN ‘‘ON’’ position. Compressor, condenser fan motor, and agitator motor will
start and begin forming an ice bank. When full ice bank has been formed, compressor and condenser fan
motor will stop but agitator motor will continue to operate circulating ice water bath in water tank.
7. Install hood and secure with one screw. Make sure O-ring is installed on screw before installing.
8. Connect drip tray drain hose as follows:
NOTE: Drip tray drain hose routed to a waste container is not recommended due to sanitation and
cleaning problems. Connection of drain hose to a permanent drain is recommended.
Содержание SPIRIT
Страница 6: ......
Страница 7: ...2 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 11: ...6 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 17: ...12 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 21: ...16 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 40: ...35 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...