Trouble
Remedy
Probable Cause
NOTE: If overload protector cuts out compressor, condenser fan motor will continue to operate;
otherwise; troubleshooting condenser fan motor problem is same as for ‘‘COMPRESSOR DOES NOT
OPERATE’’ paragraph plus the following:
CONDENSER FAN MOTOR
NOT OPERATING.
A.
Jumper cord loose or
disconnected
A.
Tighten connections or replace
cord.
B.
Fan blade obstructed.
B.
Remove obstruction.
C.
Inoperative condenser fan
motor.
C.
Replace condenser fan motor as
instructed.
AGITATOR MOTOR NOT
OPERATING.
A.
Unit power cord or
refrigeration assembly power
cord unplugged.
A.
Plug in Unit power cord or
refrigeration assembly power
cord.
B.
No power source. Blown fuse
or tripped circuit breaker.
B.
Replace fuse or reset circuit
breaker. (Note: Fuse is not part of
Unit.)
C.
Agitator motor propeller
obstructed.
C.
Remove obstructions.
D.
Low voltage.
D.
Voltage must be at least 103 volts
at compressor terminals when
compressor is trying to start.
E.
Agitator motor pressure cutout
switch inoperative.
E.
Replace pressure cutout switch.
F.
Loose, disconnected, or
broken wiring.
F.
Tighten connections or replace
broken wiring.
G.
Inoperative agitator motor.
G.
Replace agitator motor as
instructed.
Содержание SPIRIT
Страница 6: ......
Страница 7: ...2 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 11: ...6 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 17: ...12 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 21: ...16 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 40: ...35 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...