10
317961000
SYRUP AND
PLAIN WATER
INLET LINES(8)
* This CAPPED TEE is used when converting No. 3 dispensing valve
from a still (non-carbonated) to a carbonated drink. Refer to TABLE
OF CONTENTS for conversion instructions.
DRIP TRAY
DRAIN HOSE
WATER TANK
DRAIN HOSE
POWER SWITCH
*CAPPED TEE
(CARBONATED
WATER INLET LINE)
FIGURE 3. INLET SUPPLY LINE CONNECTIONS
2. Open CO
2
cylinder shutoff valve slightly to allow lines to slowly fill with gas, then open valve fully to
back-seat valve. (Back-seating valve prevents leakage around valve shaft.)
WARNING: CO
2
displaces oxygen. Strict attention must be observed in the prevention of
CO
2
(carbon dioxide) gas leaks in the entire CO
2
and soft drink system. If a CO
2
gas leak is
suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
2
gas will experience
tremors which are followed rapidly by loss of consciousness and suffocation.
3. Check all CO
2
connections for leaks. Tighten loose connections.
4. Adjust primary CO
2
regulator for carbonator and secondary CO
2
regulators for syrup tanks (see Figure 2)
to specified pressures as follows: