INSTALLATION
This section covers cooling Unit unpacking and inspection, selecting location, installation, preparation for
operation, and Unit operation.
UNPACKING AND INSPECTION
(see Figure 5)
NOTE: The Unit was thoroughly inspected before leaving factory and the carrier has accepted and
signed for it. Any damage or irregularities should be noted at time of delivery and immediately reported
to the delivering carrier. Request a written inspection report from Claims Inspector to substantiate any
necessary claim. File claim with the delivering carrier, not with IMI Cornelius Inc.
1. After Unit has been unpacked, remove shipping tape and other packing material.
2. Remove three shipping nuts that secure drop-in refrigeration assembly in Unit.
3. Unpack LOOSE-SHIPPED PARTS. Make sure all items are present and in good condition.
Table 2. Loose-Shipped Parts
Item
No.
Part No.
Name
Qty.
4-fl 5-fl
1
317982000
Cup Rest
1 1
2
317920000
Drip Tray
1 1
3
176193000
Adapter Fitting, 7/16-20 male by 7/16-20 male
6 7
4
Decals (as ordered)
5
187713000
Warranity Registration Card
1 1
6
317961000
Installation Manual
1 1
IDENTIFICATION OF LOOSE-SHIPPED PARTS
1. DRIP TRAY (item 2) to be installed on Unit, then install CUP REST (item NO TAG) in drip tray.
2. ADAPTER FITTINGS (item 3) are used to connect syrup, plain water, and carbonated water source lines
to Unit syrup, plain water, and carbonated water inlet lines.
3. DECALS (item 4) are to be installed on dispensing valve covers.
SELECTING LOCATION
This Unit may be island-mounted or installed on a front or rear counter. Locate Unit so the following
requirements are satisfied.
1. Near a properly grounded electrical outlet with proper electrical requirements (SEE UNIT NAMEPLATE)
fused at 15-amps (‘‘slow-blow’’) or circuit connected through an equivalent HACR circuit breaker must be
available to the Unit. No other electrical equipment should be connected to this circuit. ALL ELECTRICAL
WIRING MUST CONFORM TO NATIONAL AND LOCAL ELECTRICAL CODES.
2. Allow sufficient clearance (15-inches vertical) above top of hood to the nearest obstruction (shelf,
cupboard, ceiling, etc.) for removal of the hood and drop-in refrigeration assembly. The front grille of the
Unit must be unobstructed to allow air to enter the hood.
INSTALLING UNIT
INSTALLING UNIT ON COUNTERTOP
(see Figure 5)
Unit inlet supply lines, power cord, drip tray drain hose, and water tank drain hose may either be routed out
back of Unit base or through hole cut in countertop under Unit. Proceed to applicable installation procedure.
Содержание SPIRIT
Страница 6: ......
Страница 7: ...2 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 11: ...6 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 17: ...12 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 21: ...16 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 40: ...35 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...