32
317961000
Trouble
Remedy
Probable Cause
ONLY SYRUP DISPENSED.
A.
Plain water inlet supply line
shutoff valve closed.
A.
Open plain water inlet supply line
shutoff valve.
B.
Carbonator power cord
unplugged from electrical
outlet.
B.
Plug carbonator power cord into
electrical outlet.
C.
Carbonator primary CO
2
regulator not properly
adjusted.
C.
Adjust carbonator primary CO
2
regulator (Reference manual
provided with carbonator).
TROUBLESHOOTING REFRIGERATION SYSTEM
COMPRESSOR DOES NOT
OPERATE.
A.
Ice bank sufficient.
A.
Refrigeration not called for.
B.
Unit POWER SWITCH in
‘‘OFF’’ position.
B.
Place POWER SWITCH in ‘‘ON’’
position.
C.
Unit power cord unplugged or
drop-in refrigeration assembly
power cord unplugged.
C.
Plug in unit power cord.
D.
No power source. Blown fuse
or tripped circuit breaker.
D.
Replace fuse or reset circuit
breaker. (Note: Fuse is not part of
unit).
E.
Low voltage.
E.
Voltage must be at least 103 volts
at compressor terminals when
compressor is trying to start.
F.
Loose, disconnected, or
broken wiring.
F.
Tighten connections or replace
broken wiring.
G.
Overload protector cut out;
overheated compressor.
Condenser fan motor not
operating as required.
G.
Compressor will cool enough to
restart. Do not overdraw cooling
capacity of unit. Refer to
‘‘CONDENSER FAN MOTOR
NOT OPERATING’’ in this
section.
H.
Inoperative overload protector
or start relay.
H.
Replace inoperative part as
instructed.
I.
Inoperative ice bank control
probe or ice bank control
module.
I.
Replace ice bank control probe
or ice bank control module.
J.
Inoperative compressor.
J.
Replace compressor.
COMPRESSOR OPERATES
CONTINUOUSLY BUT DOES
NOT FORM SUFFICIENT ICE
BANK
A.
Cooling capacity is exceeded
by over-drawing.
A.
Reduce amount of drinks drawn
per given time.
B.
Unit located in excessively hot
area or air circulation through
condense coil is restricted.
B.
Relocate Unit or check, and if
necessary, clean condenser coil
as instructed.
NOTE: Ice bank freezes from bottom of evaporator coil upward. A refrigerant leak or insufficient
charge might show an ice bank at bottom and not at top of evaporator coil.
Содержание SPIRIT
Страница 6: ......
Страница 7: ...2 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 11: ...6 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 17: ...12 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 21: ...16 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 40: ...35 317961000 THIS PAGE LEFT BLANK INTENTIONALLY ...