![Copper Mountain Technologies PLANAR TR1300/1 Скачать руководство пользователя страница 223](http://html1.mh-extra.com/html/copper-mountain-technologies/planar-tr1300-1/planar-tr1300-1_programming-manual_2666189223.webp)
COM Server Commands
223
SCPI.SENSe(
Ch
).CORRection.COLLect.METHod.RESPonse.SHORt
Object Type
Property (write only)
Data Type
Long
Target
Channel
Ch
,
Ch
Description
Selects the port and sets the response calibration (Short) type for the
calculation of the calibration coefficients on completion of the
calibration executed by the
SCPI.SENSe(Ch).CORRection.
COLLect.SAVE
method.
Range
from 1 to 2
Out of Range
An error occurs.
Syntax
app.SCPI.SENSe(Ch).CORRection.COLLect.METHod.
RESPonse.SHORt = 1
Equivalent
Softkeys
None