Inverter Specifications
A–4
976-0043-01-01
Theory of Operation
The
Sine Wave Plus
employs a patented inverter design. This design uses
a combination of three transformers, each with its own low frequency
switches, coupled in series and driven by separate interconnected micro-
controllers. In essence, it is three inverters linked together by their
transformers.
Sine Wave Plus
Waveform
By mixing the outputs from the different transformers, a sine wave is
produced. This waveform is shown in
Figure A-2, “Sine Wave Plus
Inverter Output Waveform” on page A–5
. Notice the “steps” form a
staircase that is shaped like a sine wave. The total harmonic distortion in
this sine wave approach is typically 3-5%. The multi-stepped output is
formed by modulation of the voltage through mixing of the transformers
in a specific order. Anywhere from 34-52 “steps” per AC cycle are
present in the waveform. The heavier the load or lower DC input voltage
the more steps there are in the waveform.
This type of inverter solves many of the problems associated with high
frequency or ferroresonant sine wave inverters. The low frequency
method described has excellent surge ability, high efficiency (typically 85
to 95%), good voltage and frequency regulation, and low total harmonic
distortion.
Figure A-1
Sine Wave Plus
Simple Block Diagram
Batteries
Low Frequency
H-Bridge
Low Frequency
H-Bridge
Low Frequency
H-Bridge
Transformer
Transformer
Transformer
AC Loads
Micro-controllers
Bridges are “mixed” by
Micro-controllers
controlling the H-Bridges
Sine Wave Plus Inverter Charger
Содержание SW 2524
Страница 1: ...Sine Wave Plus Inverter Charger Owner s Manual Smart choice for power www xantrex com SW 2524 SW 2548...
Страница 2: ......
Страница 3: ...Sine Wave Plus Inverter Charger Owner s Manual...
Страница 24: ...xxii...
Страница 26: ...xxiv...
Страница 82: ...2 48...
Страница 101: ...DC Wiring 976 0043 01 01 3 19 Figure 3 9 BTS RJ11 Port Location and Installation BTS RJ11 Port DC End of the Inverter...
Страница 105: ...DC Wiring 976 0043 01 01 3 23 Figure 3 13 DC Connections to a Single Inverter...
Страница 107: ...DC Wiring 976 0043 01 01 3 25 Figure 3 14 DC Connections to Dual Inverters...
Страница 126: ...3 44...
Страница 127: ...4 Functional Test Chapter 4 Functional Test explains how to conduct a functional test of the inverter...
Страница 132: ...4 6...
Страница 139: ...Menu Map 976 0043 01 01 5 7 Figure 5 4 User Menu Map Part 2...
Страница 141: ...Menu Map 976 0043 01 01 5 9 Figure 5 6 Basic Setup Menu Map Part 2...
Страница 143: ...Menu Map 976 0043 01 01 5 11...
Страница 144: ...Navigation 5 12 976 0043 01 01...
Страница 145: ...Menu Map 976 0043 01 01 5 13...
Страница 146: ...Navigation 5 14 976 0043 01 01...
Страница 189: ...Menu Item Descriptions 976 0043 01 01 7 17 Figure 7 3 Relay 11 Wiring Example to Dual Inverters with Cooldown selected...
Страница 208: ...7 36...
Страница 240: ...8 32...
Страница 241: ...9 Troubleshooting Chapter 9 contains information and procedures for troubleshooting the Sine Wave Plus...
Страница 258: ...Inverter Specifications A 10 976 0043 01 01 Figure A 6 Time versus Current for the Sine Wave Plus 2548...
Страница 268: ...B 10...
Страница 286: ...C 18...
Страница 290: ...D 4...
Страница 294: ...E 4...
Страница 316: ...I 6...
Страница 319: ...Index 976 0043 01 01 IX 3...
Страница 320: ...Index IX 4 976 0043 01 01...
Страница 321: ......