Operational Status Indicators
976-0043-01-01
8–5
AC Input Status (Green)
Status LEDs
There are two green LEDs to indicate AC status conditions.
•
AC1 LED (grid)
•
AC2 LED (generator)
AC1 (Grid)
LED
The AC1 LED indicates power has been applied to the inverter’s AC1
(grid) input terminals. When AC is initially detected, the LED blinks
slowly (once per second). If the AC source is within the user’s input
settings, the inverter will connect to the source and the LED will be ON
solid. If the AC source falls out of tolerance, the LED will start to blink
and the AC input source will be disconnected. If using BX mode or the
Grid Usage Timer, this LED will continue to blink even if the source is
within tolerance.
AC2 (Generator)
LED
The AC2 LED indicates power has been applied to the inverter’s AC2
(generator) input terminals. When AC is initially detected, the LED blinks
slowly (once per second). If the AC source is within the user’s input
settings, the inverter will connect to the source and the LED will be ON
solid. If the AC source falls out of tolerance, the LED will start to blank
and the AC input source will be dropped.
Bypass mode
If the inverter is being used in Bypass Mode, the AC1 or AC2 LEDs,
along with the Status LED will illuminate solidly, depending on which
AC input source is selected. However, the inverter will not monitor the
AC inputs for power quality.
Figure 8-3
AC Status LEDs
Содержание SW 2524
Страница 1: ...Sine Wave Plus Inverter Charger Owner s Manual Smart choice for power www xantrex com SW 2524 SW 2548...
Страница 2: ......
Страница 3: ...Sine Wave Plus Inverter Charger Owner s Manual...
Страница 24: ...xxii...
Страница 26: ...xxiv...
Страница 82: ...2 48...
Страница 101: ...DC Wiring 976 0043 01 01 3 19 Figure 3 9 BTS RJ11 Port Location and Installation BTS RJ11 Port DC End of the Inverter...
Страница 105: ...DC Wiring 976 0043 01 01 3 23 Figure 3 13 DC Connections to a Single Inverter...
Страница 107: ...DC Wiring 976 0043 01 01 3 25 Figure 3 14 DC Connections to Dual Inverters...
Страница 126: ...3 44...
Страница 127: ...4 Functional Test Chapter 4 Functional Test explains how to conduct a functional test of the inverter...
Страница 132: ...4 6...
Страница 139: ...Menu Map 976 0043 01 01 5 7 Figure 5 4 User Menu Map Part 2...
Страница 141: ...Menu Map 976 0043 01 01 5 9 Figure 5 6 Basic Setup Menu Map Part 2...
Страница 143: ...Menu Map 976 0043 01 01 5 11...
Страница 144: ...Navigation 5 12 976 0043 01 01...
Страница 145: ...Menu Map 976 0043 01 01 5 13...
Страница 146: ...Navigation 5 14 976 0043 01 01...
Страница 189: ...Menu Item Descriptions 976 0043 01 01 7 17 Figure 7 3 Relay 11 Wiring Example to Dual Inverters with Cooldown selected...
Страница 208: ...7 36...
Страница 240: ...8 32...
Страница 241: ...9 Troubleshooting Chapter 9 contains information and procedures for troubleshooting the Sine Wave Plus...
Страница 258: ...Inverter Specifications A 10 976 0043 01 01 Figure A 6 Time versus Current for the Sine Wave Plus 2548...
Страница 268: ...B 10...
Страница 286: ...C 18...
Страница 290: ...D 4...
Страница 294: ...E 4...
Страница 316: ...I 6...
Страница 319: ...Index 976 0043 01 01 IX 3...
Страница 320: ...Index IX 4 976 0043 01 01...
Страница 321: ......