Command Lines for Port Configuration
RocketLinx ES7528 Industrial Managed PoE Rack Mount User Guide
: 2000509 Rev. A
- 55
Command Lines for Port Configuration
Port Control (continued)
Port Control –
Flow Control
Switch(config-if)# flowcontrol on
Flowcontrol on for port 1 set ok!
Switch(config-if)# flowcontrol off
Flowcontrol off for port 1 set ok!
Port Status
Port Status
Switch# show interface fa1
Interface fastethernet1
Administrative Status : Enable
Operating Status : Connected
Duplex : Full
Speed : 100
Flow Control :off
Default Port VLAN ID: 1
Ingress Filtering : Disabled
Acceptable Frame Type : All
Port Security : Disabled
Auto Negotiation : Disable
Loopback Mode : None
STP Status: forwarding
Default CoS Value for untagged packets is 0.
Mdix mode is Disable.
Medium mode is Copper.
Switch# show sfp ddm
show SFP DDM information
Port 8
Temperature:N/A
Tx power:N/A
Rx power:N/A
Port 9
Temperature:64.00 C <range :0.0-80.00>
Tx power:-6.0 dBm <range : -9.0 - -4.0>
Rx power:-30.0 dBm <range: -30.0 - -4.0>
Port 10
Temperature:67.00 C <range :0.0-80.00>
Tx power:-6.0 dBm <range : -9.0 - -4.0>
Rx power:-2.0 dBm <range: -30.0 - -4.0>
Note: Administrative Status -> Port state of the port. Operating status -> Current status of the port. Duplex
-> Duplex mode of the port. Speed -> Speed mode of the port. Flow control -> Flow Control status
of the port.