Warning
RocketLinx ES7528 Industrial Managed PoE Rack Mount User Guide
: 2000509 Rev. A
- 117
Warning
Warning
The RocketLinx ES7528 provides several types of warning features for you to remotely monitor the status of the attached
devices or changes in your network. The features include Fault Relay, System Log, and SMTP E-mail Alert. The following
commands are included in this group:
•
Fault Relay
•
Event Selection
on Page 120
•
SysLog Configuration
on Page 122
•
SMTP Configuration
on Page 123
•
CLI Commands for Warnings
on Page 124
Fault Relay
The RocketLinx ES7528 provides one digital output, known as Relay
Output. The relay contacts are energized (open) for normal operation and
close under fault conditions. Fault conditions include Power Failure,
Ethernet port Link Failure, Ping Failure, and Super Ring Topology
changes. You can configure these settings in this Fault Relay Setting.
Each Relay can be assigned 1 fault condition.
Relay 1:
Click the
Relay 1
check box and then select the Event Type and
its parameters.
Event Type:
Dry Output, Power Failure, Link Failure, Ping Failure, and
Super Ring Failure. Each event type has its own parameters. You can
configure each Event Type. Each Relay has one event type.
Event Type: Dry Output
On Period (Sec):
Type the period time to turn on Relay Output. The
available time period range is 0 - 4294967295 seconds.
Off Period (Sec)
: Type the period time to turn off Relay Output. The available time period range is 0 - 4294967295 seconds.
How to Configure
: Enter turn-on and turn-off periods, when the time is reached, the system turns on or turns off the Relay
Output.
Relay turned on for 5 seconds then off for
10 seconds
.