Programming
3
3.13.6
Administration / Counter
c00
365
en
.bm
p
Fig. 3-65: Counter
counters.txtS
From the Administration / Counter screen, the user may view, enable, disable, or reset any of the
available counters. Counters are provided for each application (1-255) and for each linking group
(1-8). The view is toggled between Application and Linking view by selecting either Application or
Linking in the pull-down menu.
Each counter may be enabled by highlighting the desired type of operation in the "Status" pull-
down menu, then pressing the Enter key. When "- Backoff" is selected, the counter is enabled,
and the current count is decremented each time the tool is started in the backoff direction. The "-
Backoff" mode is not available for Linking counters.
The "Auto Reset Mode" allows the counter to operate like a batch counter. In this mode, the
counter is automatically reset to zero after the total number of rundowns (OK + NOK = Size) or
number of OK rundowns (OK = Size) equals the value programmed in the "Size" edit box.
Each counter may be reset manually by highlighting the "Reset" checkbox and pressing
<ENTER>.
Note:
The counters are not enabled, disabled, or reset until the Accept <F3> soft key is pressed,
and the correct password (if enabled) and confirmation are provided.
counters.txtE