Programming
3
Outputs
The output packet will be 2 Words long (4 bytes). When Ethernet/IP is the selected field bus, and
the "Torque / Angle Values" box is checked, the output packet is 5 words (10 bytes). The status of
all fieldbus outputs is viewable from a diagnostics screen on the TME. All outputs are updated
continuously.
WORD 0
BYTE 0
BIT 0:
Spare
BIT 1:
Linking OK
BIT 2:
Linking NOK
BIT 3:
Linking Complete
BIT 4-6:
Application/Link Select Code 1-8 (Mirror)
BIT 7:
Tool-Enable from Socket Tray
BYTE 1
BIT 0:
Tool In-Cycle
BIT 1:
Tool Reverse Switch
BIT 2:
Fault
BIT 3:
Cycle Complete
BIT 4:
Tool Ready pass-through from Input
BIT 5:
Socket Tray Application Select
BIT 6:
Socket Tray Application Select
BIT 7:
Socket Tray Application Select
WORD 1
BYTE 0
BIT 0:
Green Tool Light (Cycle OK)
BIT 1:
Cycle NOK
BIT 2:
Yellow Tool Light
BIT 3:
Torque Low
BIT 4:
Torque High
BIT 5:
Angle Low
BIT 6:
Angle High
BIT 7:
Spare
BYTE 1
BIT 0-4:
Application/Link Select Code 9-255 (Mirror)
BIT 5-7:
Spare
WORD 2
BYTE 0
ALL:
Torque
BYTE 1
ALL:
Torque
WORD 3
BYTE 0
ALL:
Torque
BYTE 1
ALL:
Torque
WORD 4
BYTE 0
ALL:
Angle
BYTE 1
ALL:
Angle